Data Sheet
Teledyne LeCroy  Automation API Reference Manual for USBTracer, USB Advisor, and Voyager USB Protocol 
Suite 
118 
7.1.3  IRecOptions::SetRecMode 
HRESULT SetRecMode ( 
[in] ERecModes rec_mode ); 
Sets the recording mode. 
Parameters 
  rec_mode  Enumerated value providing the mode to set; 
ErecModes enumerator has the following values: 
RMODE_SNAPSHOT   ( 0 ) Snapshot recording mode 
RMODE_MANUAL   ( 1 ) Manual trigger  
RMODE_USE_TRG   ( 2 ) Event trigger 
Return values 
E_INVALIDARG   Invalid recording mode was specified. 
Remarks 
The default setting of recording options is the snapshot recording mode. 
Example 
WSH: 
CurrentDir = Left(WScript.ScriptFullName, InstrRev(WScript.ScriptFullName, "\")) 
Set Analyzer = WScript.CreateObject("CATC.USBTracer") 
Set RecOptions = Analyzer.GetRecordingOptions 
RecOptions.SetRecMode 2 ' Event trigger 
C++: 