Data Sheet

USBProtocolSuiteUserManual 227
RecordingOptionsModes TeledyneLeCroyCorporation
WARNING: AllowVbuswithoutCC‐PinTermination:Thischeckboxallowsyoutooverridethe
Type‐C/PDprotocol.Thisfeatureswasaddedsothatduringdevelopmentyoucantest
theSS+protocolwithouthavingtodrivetheVbusandcomplywithotheraspectsofthe
Type‐C/PDprotocol.
WARNING: AllowVbus>5V:ThischeckboxallowsyoutogeneratevoltagesonVBusashighas20
Volts.See“VoyagerM310CAnalyzer”onpage 31.Sincethiscandamagedeviceswhich
arenottolerantofanythingmorethan5Volts,itisunwisetocheckthisunlessyouare
sureyourscriptsarewrittensothattheydonotdamageyourequipmentorcables.Itis
recommendthatyoualwaysuse5AmpcablesformostPowerDeliverExerciser
scenarios.
M310C: Misc. Type-C Analyzer Mode Recording Options
Figure 5.18: Voyager M310C: Recording Options for Type-C Analyzer Mode
SeeDescriptionofConnectorVConnbelow
PowerMea
surement
DeviceInformation
Left:Type
SeeNotebelow
SeeCCStateDetectionbelow
Analyzer Mode