Data Sheet
USBProtocolSuiteUserManual 255
RecordingOptions‐Misc.USB3.1forVoyager TeledyneLeCroyCorporation
5.4.5 Data Truncation Option
TruncateDataFields(2.0):Allowsdatafieldstobetruncatedduringrecordingin
ordertosaveAnalyzermemoryandallowrecordingofmorepackets.Entera
minimumdatalengthvalueintheBytesbox.Thesystemtruncatesthedatato
thestatedvalue(orupto5bytesmoretooptimizeoperationefficiencyinthe
Analyzerhardware).
Note:Truncationofdatamaycauseincorrecttransactionortransferdecoding.
5.5 Recording Options - Misc. USB 3.1 for Voyager
TheMisc.USB3.1tabpresentsoptionsforsettingRecordingPorts,Descrambling,
PolarityInversion,SpreadSpectrumClock,Recording/Generating,Simple Filtersand
TruncateDataFields,Simple Triggers,Clock/SpeedSelection,andM3iConnector
Termination/RxDetect.
Note:VoyagerM3x/M310/M310CdonotsupportPortConfigurations.