Instructions

42 T3VNA Programming Guide
Parameter
Type
Boolean
Parameter
Range
ON|OFF|0|1
Return 0|1
Default 0
Menu Marker > Marker Table
Example :CALCulate:MARKer:TABLe ON
3.6.1.9 Marker to Start Frequency
(:CALCulate:MARKer[1]|2|3|4|5|6|7|8[:SET]:START)
Command
Format
:CALCulate:MARKer[1]|2|3|4|5|6|7|8[:SET]:START
Instruction Sets the start frequency to the value of the specified marker frequency. This
command is not available in zero span.
If the Marker is OFF, it will set the marker on center.
Parameter
Type
None
Parameter
Range
None
Return None
Default None
Menu Marker > M→Start Freq
Example :CALCulate:MARKer1:START
3.6.1.10 Marker to Stop Frequency
(:CALCulate:MARKer[1]|2|3|4|5|6|7|8[:SET]:STOP)
Command
Format
:CALCulate:MARKer[1]|2|3|4|5|6|7|8[:SET]:STOP
Instruction Sets the stop frequency to the value of the specified marker frequency. This
command is not available in zero span .
This command is valid when the Marker is on.
Parameter
Type
None
Parameter
Range
None
Return None
Default None
Menu Marker > Marker→Stop Freq
Example :CALCulate:MARKer1:STOP
3.6.1.11 Marker to Center Frequency
(:CALCulate:MARKer[1]|2|3|4|5|6|7|8[:SET]:CENTer)
Command
Format
:CALCulate:MARKer[1]|2|3|4|5|6|7|8[:SET]:CENTer
Instruction This command sets the center frequency equal to the specified marker
frequency, which moves the marker to the center of the screen. This command
is not available in zero span.
This command is valid when the Marker is on.