Instructions
38 T3VNA Programming Guide
3.5.8.6 QPD Time([:SENSe]:QPD:DWELl:TIME)
Command
Format
[:SENSe]:QPD:DWELl:TIME < time >
[:SENSe]:QPD:DWELl:TIME?
Instruction Sets QPD Time
Gets QPD Time
Parameter
Type
Float,unit:s、ms、us
Parameter
Range
0us ~ 10s(qusai-peak: 900us ~ 30ks)
Return
Float,unit: s
Default 50ms
Menu Sweep > QPD Time
Example :QPD:DWELl:TIME 10s
3.5.9 Display Subsection
3.5.9.1 Grid Brightness
(:DISPlay:WINDow:TRACe:GRATicule:GRID:BRIGhtness)
Command
Format
:DISPlay:WINDow:TRACe:GRATicule:GRID:BRIGhtness <value>
:DISPlay:WINDow:TRACe:GRATicule:GRID:BRIGhtness?
Instruction Sets grid brightness.
Gets grid brightness.
Parameter
Type
Integer
Parameter
Range
0 ~ 100
Return Integer
Default 30%
Menu Display > Grid Brightness
Example :DISPlay:WINDow:TRACe:GRATicule:GRID:BRIGhtness 50
3.5.9.2 Display Line on-o
(:DISPlay:WINDow:TRACe:Y:DLINe:STATe)
Command
Format
:DISPlay:WINDow:TRACe:Y:DLINe:STATe OFF|ON|0|1
:DISPlay:WINDow:TRACe:Y:DLINe:STATe?
Instruction Toggles the display line between on and off.
Gets the display line state.
Parameter
Type
Enumeration
Parameter
Range
OFF|ON|0|1
Return 0|1
Default OFF
Menu Display > Display Line
Example :DISPlay:WINDow:TRACe:Y:DLINe:STATe ON