Data Sheet
3
SPECIFICATIONS
T3PSU3000
Channel CH1 output voltage: 0 ~ 32 V, output current: 0 ~ 3.2 A
CH2 output voltage: 0 ~ 32 V, output current: 0 ~ 3.2 A
CH3 output voltage: 2.5 / 3.3 / 5.0 V, output current: 3.2 A
Display 4.3 inch color TFT-LCD
5 digits voltage 4 digits current
Resolution 1 mV / 1 mA
Program Accuracy Voltage ± (0.03 % of reading + 10 mV)
Current ± (0.3 % of reading + 10 mA)
Readback Accuracy Voltage ± (0.03 % of reading + 10 mV)
Current Current ± (0.3 % of reading +10 mA)
Constant Voltage
Mode
Line Regulation ≤ 0.01% + 3 mV
Load Regulation ≤ 0.01% + 3 mV
Ripple & Noise ≤ 1 mVrms (5 Hz ~ 1 MHz)
Recovery Time < 50 μs (50 % load change, minimum load 0.5 A)
Constant Current
Mode
Line Regulation ≤ 0.2 % + 3 mA
Load Regulation ≤ 0.2 % + 3 mA
Ripple & Noise ≤ 3 mArms
Parallel Mode Line Regulation ≤ 0.01% + 3 mV
Load Regulation ≤ 0.01% + 3 mV
Series Mode Line Regulation ≤ 0.01% + 5 mV
Load Regulation ≤ 300 mV
CH3 Output Voltage (2.5 / 3.3 / 5 V) ± 8 %
Line Regulation ≤ 0.01% + 3 mV
Load Regulation ≤ 0.01% + 3 mV
Ripple & Noise ≤ 1 mVrms (5 Hz ~ 1 MHz)
Locking Key Yes
Memory Save / Recall 5 Sets
Max Output Power 220 W
Power Source AC 100 V / 120 V / 220 V / 230 V ± 10 % 50/60 Hz
Standard Conguration Interface USB Device, LAN
Insulation Case to Terminal ≥ 20 MΩ (DC 500 V)
Case to AC line ≥ 30 MΩ (DC 500 V)
Operating Environment Outdoor Usage: Elevation: ≤ 2000 m, Environment Temperature 0~40 °C
Relative Humidity ≤ 80 %, Installation Level: II, Pollution Level: 2
Storage Environment Environment Temperature: -10~70 °C, Relative Humidity ≤ 70 %
Dimension 225 (W) × 143 (H) × 278 (D) mm
Weight ≈ 8.0 kg
Ordering information
Product Name T3PS3000: 3 channels independent output, min resolution 1 mV / 1 mA, USB Device & LAN,
4.3 inch LCD display
Standard Accessories USB Cable -1
Quick Start -1
Product Certicate -1
Calibration Certicate -1
Power cord -1
Output Test Cord -2 Sets