Data Sheet

Models and Specications
T3EL15060P T3EL50015P
Range Low High Low High
Power 300 W 300 W 300 W 300 W
Voltage 1 V - 150 V 1 V -150 V 2.5 V - 500 V 2.5 V - 500 V
Current 0 - 6 A 0 - 60 A 0 - 1.5 A 0 - 15 A
Minimum Operating
Voltage (DC)
1 V - 6 A 1 V - 60 A 2.5 V - 1.5 A 2.5 V - 15 A
Static Mode
Constant Current Mode
Range 0 - 6 A 0 - 60 A 0 - 1.5 A 0 - 15 A
Resolution 0.2 mA 2 mA 0.05 mA 0.5 mA
Constant Resistance
Mode
Range
0.01666 - 500 (300 W / 15 V)
0.1666 - 5k (300 W / 150 V)
0.16666 - 5k (300 W / 50 V)
1.6666 - 50k (300 W / 500 V)
Constant Voltage Mode
Range 1 V - 15 V 1 V - 150 V 2.5 V - 50 V 2.5 V - 500 V
Resolution 0.5 mV 5 mV 1 mV 10 mV
Constant Power Mode
Range 0 W - 30 W (6 A) 0 W - 300 W (60 A) 0 W - 30 W (1.5 A) 0 W - 300 W (15 A)
Resolution 1 mW 10 mW 1 mW 10 mW
Dynamic Mode
Timers T1 & T2
Fast Mode 0.05 ms - 30 ms, Resolution 1 us 0.05 ms - 30 ms, Resolution 1 us
Normal Mode 30 ms - 30 s, Resolution 1 ms 30 ms - 30 s, Resolution 1 ms
Constant Current Mode
Range 0 - 6 A 0 - 60 A 0 - 1.5 A 0 - 15 A
Resolution 0.2 mA 2 mA 0.05 mA 0.5 mA
Constant Resistance
Mode
Range
0.01666 - 500 (300 W / 15 V)
0.1666 - 5k (300 W / 150 V)
0.16666 - 5k (300 W / 50 V)
1.6666 - 50k (300 W / 500 V)
Functions
Sequence
Normal Maximum Steps: 1000, Step Time: 1 ms - 999h 59min 59sec (3599940 sec)
Fast Maximum Steps: 1000, Step Time: 25 us - 600 ms (600 sec)
Battery Test Automation Maximum Test Time: 999h 59min 59sec (3599940 sec), Maximun Test AH: 9999.99 Ah
Test Function OCP Autotest Function, OPP Autotest Function
Soft Start Yes Yes
Other
In / Out Terminals Analog External Control, Current Monitor Output, Trigger In / Out BNC
Preset Data 10 Sets 10 Sets
Protection OCP, OPP, UVP, OVP, OTP, RVP
Interface USB, Analogue Control
Power 100 VAC - 120 VAC / 200 VAC - 240 VAC, 47 Hz - 63 Hz
Dimensions and Weight Width: 213.8mm, Height: 124mm, Depth: 400.5mm, Weight: 7.5kg
Warranty 3 Year Return To Teledyne LeCroy
SPECIFICATIONS