Datasheet

Maximum Recommended
Model Bandwidth Input R Input C Attenuation Voltage Diameter Oscilloscope
PP005A 500 MHz 10 MΩ 11 pF 10:1 500 V 5 mm 1, 2, 12, 13
PP006A 500 MHz 10 MΩ 12 pF 10:1 600 V 5 mm 3, 11
PP007-WS 500 MHz 10 MΩ 9.5 pF 10:1 400 V 2.5 mm 4
PP007-WR 500 MHz 10 MΩ 9.5 pF 10:1 400 V 2.5 mm 5, 7, 9
PP008 500 MHz 10 MΩ 9.5 pF 10:1 400 V 2.5 mm 4, 6, 8
PP009 500 MHz 10 MΩ 9.5 pF 10:1 400 V 5 mm 4, 6, 8
PP010 200 MHz 10 MΩ 12.5 pF 10:1 600 V 5 mm 10
PP011 500 MHz 10 MΩ 9.5 pF 10:1 400 V 5 mm 5, 7, 9
Recommended Oscilloscope
1 9300 Series 8 WaveSurfer Xs Series ( 600 MHz)
2 LC Series 9 WaveSurfer Xs Series (1 GHz)
3 LT Series 10 WaveJet Series ( 200 MHz)
4 WaveSurfer 400 Series 11 WaveJet Series ( 350 MHz)
5 WaveRunner 6000 Series 12 WavePro 900 Series
6 WaveRunner Xi Series ( 600 MHz) 13 WavePro 7000 Series
7 WaveRunner Xi (1 GHz–2 GHz)
ORDERING INFORMATION PRODUCT CODE
÷10, 500 MHz 10 MΩ Passive Probe PP005A
÷10, 500 MHz 10 MΩ Passive Probe PP006A
÷10, 500 MHz 10 MΩ Passive Probe PP007-WS-1
÷10, 500 MHz 10 MΩ Passive Probe PP007-WR-1
÷10, 500 MHz 10 MΩ Passive Probe PP008
÷10, 500 MHz 10 MΩ Passive Probe PP009
÷10, 200 MHz 10 MΩ Passive Probe PP010
÷10, 500 MHz 10 MΩ Passive Probe PP011
PASSIVE PROBES
248 1-800-5-LeCroy
PROBES AND
PROBE ACCESSORIES
Passive probes are the standard probe provided with most oscilloscopes. Typical
passive probes provide a 10:1 attenuation and feature a high input resistance of
10 MΩ. This high input resistance means that passive probes are the ideal tool for
low frequency signals since circuit loading at these frequencies is minimized. Passive
probes are designed to handle voltages of at least 400 V, some as high as 600 V.
LeCroy passive probes feature an attenuation sense pin which tells the oscilloscope
to scale the waveforms automatically requiring no user input.
Each passive probe is recommended for a certain oscilloscope, using the right
passive probe with the right oscilloscope means that the probe can be properly
compensated across the entire bandwidth. Using probes with a different oscilloscope
will only let you compensate for low frequencies.
Features:
Bandwidth from 200 MHz to 500 MHz
Probe encoding ring for automatic scale factor readout on LeCroy oscilloscopes