Datasheet
SPECIFICATIONS CP031
*†
CP030
*†
ELECTRICAL CHARACTERISTICS
Max. Continuous Input Current 30 A 30 A
Bandwidth 100 MHz 50 MHz
Max. Peak Current at Pulse Width 50 A ≤ 10 µs 50 A ≤ 10 µs
Rise Time (typical) ≤ 3.5 ns ≤ 7 ns
Minimum Sensitivity 20 mA/div 20 mA/div
Max. In-Phase Current – –
Low-Frequency Accuracy 1% 1%
AC Noise ≤ 2.5 mA ≤ 2.5 mA
Coupling AC, DC, GND AC, DC, GND
GENERAL CHARACTERISTICS
Cable Length 1.5 m 1.5 m
Weight 240 g 240 g
Max. Conductor Size (diameter) 5 mm 5 mm
Interface ProBus, 1 MΩ only
‡
ProBus, 1 MΩ only
‡
Usage Environment Indoor Indoor
Operating Temperature 0 ˚C to 40 ˚C 0 ˚C to 40 ˚C
Max. Relative Humidity 80% 80%
Max. Altitude 2000 m 2000 m
Maximum Insulated Wire Voltage 300 V CAT I, 150 V CAT II 300 V CAT I
CURRENT PROBES
270 1-800-5-LeCroy
PROBES AND
PROBE ACCESSORIES
0.001
0.01
0.1
1
10
Frequency (Hz
)
Insertion
Impedance
(Ω)
0
5
10
15
20
25
30
35
Frequency (Hz)
Current
(Arms)
Frequency (Hz)
0.001
0.01
0.1
1
10
Insertion
Impedance
(Ω)
0
5
10
15
20
25
30
35
Frequency (Hz)
Current
(Arms)
CP031 – 30 A, 100 MHz
CP031 – 30 A, 100 MHz
CP030 – 30 A, 50 MHz
CP030 – 30 A, 50 MHz
ORDERING INFORMATION PRODUCT CODE
30 A; 100 MHz Current Probe – CP031
AC/DC; 30 A
rms
; 50 A
peak
Pulse
30 A; 50 MHz Current Probe – CP030
AC/DC; 30 A
rms
; 50 A
peak
Pulse
30 A; 50 MHz Current Probe – AP015
AC/DC; 30 A
rms
; 50 A
peak
Pulse
150 A; 10 MHz Current Probe – CP150
AC/DC; 150 A
rms
; 500 A
peak
Pulse
500 A; 2 MHz Current Probe – CP500
AC/DC; 500 A
rms
; 700 A
peak
Pulse
* Guaranteed at 23 °C ±3 °C
†
The CP031 and CP030 are compatible with LeCroy X-Stream oscilloscopes running firmware version 4.3.1.1 or greater.
‡
Requires AP-1M for use with 50 Ω input only oscilloscopes.
Maximum Input Current vs. Frequency
Insertion Impedance vs. Frequency
(typical)
Maximum Input Current vs. Frequency
Insertion Impedance vs. Frequency
(typical)