Data Sheet

18
PROBES
ZS Series High Impedance
Active Probes
ZS1000, ZS1000-QUADPAK
ZS1500, ZS1500-QUADPAK
High input impedance (1 MΩ), low 0.9 pF input capacitance
and an extensive set of probe tips and ground accessories
make these low-cost single-ended probes ideal for a wide
range of applications. The ZS Series is available up to
4GHz bandwidth.
Differential Probes
(200 MHz – 1.5 GHz)
ZD1500, ZD1000,
ZD500, ZD200
AP033
High bandwidth, excellent common-mode rejection ratio
(CMRR) and low noise make these active differential probes
ideal for applications such as automotive electronics and
data communications. AP033 provides 10x gain for high-
sensitivity measurement of series/shunt resistor voltages.
Active Voltage/Power
Rail Probe
RP4030
Specically designed to probe a low impedance power/
voltage rail. The RP4030 has 30V built-in offset adjust,
low attenuation (noise), and high DC input impedance with
4GHz of bandwidth and a wide assortment of tips and
leads, including solder-in and U.FL receptacle connections.
High Voltage
Fiber Optically-isolated Probe
HVFO103
The HVFO103 is a compact, simple, affordable probe for
measurement of small signals (gate-drives, sensors, etc.)
floating on an HV bus in power electronics designs, or for
EMC, EFT, ESD, and RF immunity testing sensor monitoring.
Suitable for up to 35kV common-mode. 140 dB CMRR.
HVD Series High Voltage
Differential Probes
HVD3102, HVD3106 (1 kV)
HVD3206 (2 kV)
HVD3605 (6 kV)
Available with 1, 2 or 6kV common-mode ratings. Excellent
CMRR (65 dB @ 1 MHz) at high frequencies is combined
with low inherent noise, wide differential voltage range, high
offset voltage capabilities, and 1% gain accuracy. The ideal
probe for power conversion system test.
High Voltage
Passive Probes
HVP120,
PPE4KV, PPE5KV, PPE6KV
The HVP and PPE Series includes four xed-attenuation
probes covering a range from 1 kV to 6 kV. These probes
are ideal for lightning/surge or EFT testing, or for probing
in-circuit beyond the range of a LV-rate passive probe.
Differential Amplier
DA1855A
DXC100A, DXC200
DXC-5100, DA101
The DA1855A is a stand-alone high performance 100 MHz
differential amplier with 100 dB CMRR and HV common-
mode when combined with a suitable probe pair (sold
separately). It is ideal for semiconductor device conduction/
switching loss or high sensitivity voltage measurements.
Current Probes
CP030, CP030-3M, CP030A
CP031, CP031A
CP150, CP150-6M
CP500, DCS015
Available in bandwidths up to 100 MHz with peak currents
of 700 A and sensitivities to 1 mA/div. Extra-long cables
(3 or 6 meters) available on some models. Ideal for
component or power conversion system input/output
measurements. DCS015 deskew calibration source also
available.
Probe and Current Sensor
Adapters
TPA10, TPA10-QUADPAK
CA10, CA10-QUADPAK
TPA10 adapts supported Tektronix TekProbe-compatible
probes to Teledyne LeCroy ProBus interface. CA10 is a
programmable adapter for third-party current sensors that
have voltage or current outputs proportional to measured
current. QUADPAKs of four pieces each are available.
Teledyne LeCroy offers an extensive range of probes to meet virtually every probing need.