User manual

l Data Source (DS) No.- When only one data source is employed, set this parameter to 0 (zero), otherwise,
set to the desired data source
l Carries (UUID) - Select from the list to apply the Universal Unique Identifier (UUID) of the application layer
that RFCOMM traverses to from the following:
o
OBEX
o
SPP
o
encap asyncPPP
o
Headset
o
FAX
o
Hands Free
o
SIM Access
o
VCP
o
UDI
o
-Raw Data-
Adding, Deleting, and Saving RFCOMM Parameters
1. From the Set Initial Decoder Parameters window, click on the RFCOMMtab.
2. Set or select the RFCOMMdecoder parameters.
3. Click on the ADD button. The Initial Connection window displays the added parameters.
Figure 3.16 - Parameters Added to Decoder
4. To delete a parameter from the Initial Connections window, select the parameter and click on the
Delete button.
5. Decoder parameters cannot be edited. The only way to change a parameter is to delete the original as
described above, and recreate the parameter with the changed settings and selections and then click on
the Add button.
6. RFCOMM parameters are saved when the template is saved as described in on page 1
3.2.4.2 RFCOMM Missing Decode Information
ComProbe software usually determines the protocol carried in an RFCOMM payload by monitoring previous
traffic. However, when this fails to occur, the Missing Decoding Information Detected dialog appears and
requests that the user supply the missing information.
The following are the most common among the many possible reasons for a failure to determine the traversal:
TELEDYNE LECROY Chapter 3 Configuration Settings
28 Frontline BPA low energy Hardware & Software User Manual