User manual

Figure 4.104 - Delta fields
4.5.6 Switching Between Live Update and Review Mode
The Event Display and Frame Display windows can update to display new data during live capture, or be
frozen to allow data analysis. By default, the Event Display continually updates with new data, and the Frame
Display is locked.
1.
Make sure the Lock icon is active so the display is locked and unable to scroll.
2.
Click the Unlock icon again to resume live update.
The analyzer continues to capture data in the background while the display is locked. Upon resuming live update,
the display updates with the latest data.
You can have more than one Event Display or Frame Display window open at a time. Click the Duplicate
View icon to open additional Event or Frame Display windows. The lock/resume function is independent on
each window. This means that you can have two Event Display windows open simultaneously, and one window
can be locked while the other continues to update.
4.5.7 Data Formats and Symbols
4.5.7.1 Switching Between Viewing All Events and Viewing Data Events
By default, the analyzer on the Event Display dialog shows all events
1
that include:
l Data bytes
l Start-of-frame
l End-of-frame characters
l Data Captured Was Paused.
1
An event is anything that happens on the circuit or which affects data capture. Data bytes, control signal changes, and long
and short breaks are all events, as are I/O Settings changes and Data Capture Paused and Resumed.
TELEDYNE LECROY Chapter 4 Capturing and Analyzing Data
150 Frontline BPA low energy Hardware & Software User Manual