Users Manual Instruction Manual
94
CATC FIREINSPECTOR 2.01 CHAPTER 7
User’s Manual Traffic Generation
response 4 Value specifies the acknowledge code to be automatically sent in response to a
response packet.
Possible values:
complete or 1
pending or 2
busy_x or 4
busy_a or 5
busy_b or 6
address_error or 7
repeat_mode 16 Possible values:
continuous or 0
Any number to define how many repetitions to make for the packets following this
control packet, up to the end of the repeat_stop packet.
gap_cnt or
gap_count
6 Value (0-63) sets gap count on the bus during bus reset.
Table 7-4: Keys for Asynchronous Packet Fields
Key Code Size (bits) Description
speed n/a Possible values:
0 or S100 (100 Mbit/s)
2 or S200 (200 Mbit/s)
4 or S400 (400 Mbit/s)
dest_id or dst_id 16 Destination identifier
tl 6 Transaction label
rt 2 Retry code
pri 4 Priority
dest_off1 16 Destination offset (high word in second quadlet)
dest_off2 32 Destination offset (low double word in third quadlet)
quadlet or
quadlet_data
32 Quadlet data
data_len or
datalen
16 Data length (in bytes)
ext_tcode 16 Extended tcode
rcode 4 Response code
res1 12 Reserved field (in second quadlet)
res2 32 Reserved field (in third quadlet)
Table 7-5: Keys for Isochronous Packet Fields
Key Code Size (bits) Description
speed n/a Possible values:
0 or S100 (100 Mbit/s)
2 or S200 (200 Mbit/s)
4 or S400 (400 Mbit/s)
tag 2 Isochronous data format tag (isochronous data block packet only)
Table 7-3: Control Packet Keys (Continued)
Key Code Size (bits) Description