Product Description Product Code
ProBus Current Adapter CA10
Set of 4 CA10, ProBus Current Adapter CA10-QUADPAK
Customer Service
Teledyne LeCroy oscilloscopes and probes are designed, built, and tested to ensure high reliability. In the unlikely event you experience
difculties, our digital oscilloscopes are fully warranted for three years and our probes are warranted for one year. This warranty includes:
•
No charge for return shipping
•
Long-term 7-year support
•
Upgrade to latest software at no charge
Compatibility*
HDO4000
HDO6000
HDO8000
MDA800
WaveRunner 6 Zi
WaveRunner HRO 6Zi
WavePro 7Zi/Zi-A
WaveMaster 8 Zi/Zi-A/Zi-B
LabMaster 9 Zi-A
* The CA10 requires the Teledyne LeCroy oscilloscope to be running
rmware version 7.8.x or greater.
Included with Standard Conguration CA10
Description Qty
CA10 ProBus Current Adapter
1
Heat-Shrink tubing (6" length)
1
Removable Labels (sheet of 20)
1
Included with Standard Conguration CA10-QUADPAK
Description Qty
CA10 ProBus Current Adapter
4
Carrying Case
1
Heat-Shrink tubing (24" length)
1
Removable Labels (sheet of 20)
4
Specications
Input Coupling DC, AC, Both
Input Termination 1MΩ or 50Ω
Programmable Bandwidth Filters Full, 200 MHz, 20 MHz
Transformer/Transducer Interface BNC
Scaling Factors Programmable
Resistive Termination (if required) Customizable (see Customizing the
CA10 gure above)
Oscilloscope Interface
Teledyne LeCroy ProBus
Note: Some third party devices will require a separate power supply or
batteries. The CA10 does not have the ability to supply the power to
these devices.
Ordering Information
CA10 ProBus current adapter attached to a Danisense Current
Transducer. Also shown is a Pearson Current Transformer and a
PEM-UK Rogowski Coil, which are also third party devices that can
be used with the CA10.
2 3
J3
1
R4R14R13
Customizable Circuit
Transformer/
Transducer
Connector
L1
0 ohm
C8 C7
23
J2
1
MDA/Oscilloscope
Input BNC
Connector
Customizing the CA10
It is possible to customize the CA10
through the addition of shunt resistors
and other bandwidth ltering components.
A schematic of the user-installable
components is shown here. The CA10
comes from the factory with a 0Ω (short)
installed in the L1 location, and no
components in the other locations shown.
CAUTION: The secondary of a current transformer (CT), when unterminated, can generate hazardous open circuit voltages when
energized. These voltages could be dangerous to personnel and damage the oscilloscope. If the CA10 is used with an unterminated
current transformer, you must install a suitably rated terminating resistor in the CA10 before energizing the CT. Download the CA10
ProBus Current Adapter Operator’s Manual from teledynelecroy.com for customization instructions.