Users Manual Instruction Manual
283
CATC BTTRAINER 2.11 CHAPTER
User’s Manual
PowerControl
Mode
1 Byte
0 Fixed Tx output power Values defined for LMP_TestControl command
1 Adaptive power control
PollPeriod**
1 Byte
Example: 1 - POLL is sent every
master-to-slave slot
Values defined for LMP_TestControl command.
Units: 1.25 ms
In Closed Loopback mode, set to 0 (not
applicable)
PacketType
1 Byte
POLL 0x01 Values defined for LMP_TestControl command
NULL 0x00
DM1 0x03
HV1 0x05
HV2 0x06
HV3 0x07
DV 0x08
DH1 0x04
DM3 0x0A
DH3 0x0B
DM5 0x0E
DH5 0x0F
AUX1 0x09
Reserved
NumOf
Packets
2 Bytes
0x0001 – 0xFFFF Number of data packets to transmit. After
NumOfPackets are transmitted, only NULL or
POLL packets will be sent to maintain the
connection.
Time
Length
2 Byte
0x0000 – 0xFFFF (ms) Amount of time to send data packets. After
TimeLength, only NULL-POLL packets will be
transmitted to maintain the connection.
TimeLength will override NumOfPackets
parameter if TimeLength value is not zero.