Users Manual Owner's manual

7
BTTracer Protocol Analyzer User’s ManualCATC SW Version 2.20
1.6 Specifications
Package
Power Requirements
90-264VAC, 47-63Hz (universal input), 100W maximum
Environmental Conditions
Switches
LEDs
Recording Memory Size
512 M x 8-bit DRAM for traffic data capture, timing, state and other data.
Certification
FCC (Class A), CE Mark
Dimensions: UPAS 2500H
12.2 x 12.2 x 3.5 inches
(31.1 x 31.1 x 8.9 cm)
Connectors: AC power connection
external clock input (EXT CLK, BNC)
host connection (USB, type ‘B’)
data connector (Data In/Out, 25-pin DB)
Weight: UPAS: 9.5 lbs. (4.3 kg)
Operating Range: 0 to 55 °C (32 to 131 °F)
Storage Range: -20 to 80 °C (-4 to 176 °F)
Humidity: 10 to 90%, non-condensing
Power: on/off
Manual Trigger: when pressed forces a trigger event
UPAS:
Power (PWR): illuminated when the UPAS is powered on.
Status (STATUS) Illuminated when the analyzer is functioning properly
BTTracer Module:
Recording (REC): illuminated when the analyzer is actively recording data.
Triggered (TRG): illuminated during power-on testing, and when the analyzer
has detected a valid trigger condition.
Synchronized
(SYNC):
flashes during acquisition of the traffic hop sequence, illu-
minated when the analyzer is locked to the hop sequence.