Manual
Teledyne LeCroy Automation API for PETracer/PETrainer
71
5.3.8 IPERecOptions2::SetInhibit
HRESULT SetInhibit(
[in] EDirection direction,
[in] BOOL inhibit )
Inhibits one of the traffic directions.
Parameters:
direction
Enumerated value that provides traffic direction to inhibit; EDirection has
the following values:
DIRECTION_UPSTREAM (0) - upstream traffic
DIRECTION_DOWNSTREAM (1) - downstream traffic
inhibit
Specifies whether to inhibit traffic specified in the direction parameter
Remarks
Implemented for PETracer ML and PETracer EML. Not implemented for PETracer x1.