Manual
Teledyne LeCroy Automation API for PETracer/PETrainer
56
5.1.3 IRecOptions::SetRecMode
HRESULT SetRecMode (
[in] ERecModes rec_mode )
Sets the recording mode.
Parameters
rec_mode
Enumerated value providing the mode to set; ERecModes enumerator
has the following values:
RMODE_SNAPSHOT ( 0 ) – snapshot recording mode
RMODE_MANUAL ( 1 ) – manual trigger
RMODE_USE_TRG ( 2 ) – event trigger
Return values
E_INVALIDARG Invalid recording mode was specified
Remarks
The default setting of recording options is a “snapshot” recording mode.
Example
WSH:
Set Analyzer = WScript.CreateObject( “CATC.PETracer” )
Set RecOptions = Analyzer.GetRecordingOptions( )
RecOptions.SetRecMode 2 ' Event trigger
C++: