5.1 IRecOptions interface
The IRecOptions
interface is a dual interface for PERecOptions object.
IRecOptions implements the following methods:
Load
Save
SetRecMode
SetBufferSize
SetPostTriggerPercentage
SetTriggerBeep
SetSaveExternalSignals
SetTraceFileName
Reset
Note: All methods of the IRecOptions interface are also available in the IPERecOptions (see Page 57) and the
IPERecOptions2 (see Page 57) interfaces.
5.1.1 IRecOptions::Load
HRESULT Load (
[in] BSTR ro_file_name )
Loads recording options from the specified file. The load options are:
Loads the whole Recording Options (.rec)
Loads only the Recording Rules portions of the recording options (.rr)
Loads only the Probe Settings portions of the recording options (.ps). This option only applies to the
Summit T3-16, T3-8, T28 and T24 Protocol Analyzers.
Parameters
ro_file_name
String that provides the full pathname to the recording options file
Return values
ANALYZERCOMERROR_UNABLEOPENFILE Unable to open file
Remarks
Example
WSH:
CurrentDir = Left( WScript.ScriptFullName, InstrRev( WScript.ScriptFullName, “\” ) )
Set Analyzer = WScript.CreateObject( “CATC.PETracer” )
Set RecOptions = Analyzer.GetRecordingOptions( )
RecOptions.Load( CurrentDir & "Input\rec_options.rec" )
C++: