Each of the six possible patch modules (Model MDC-P72N) features 72 SC/APC cross-connect adapters for a total of 432 possible
subscriber cross connections. Model MDC-P72N-F100D includes the Model MDC-P72N connected to 100 ft (~30.5 m) of Dri-Flex™
OSP cable containing 250 µm fiber furcated to 900 µm loose tubing with an SC/APC connector.
The following illustration shows a deployed cabinet along with a partially cabled rear compartment.
MDC-CB WITH REAR COMPARTMENT IN-CABINET SPLICING
The distribution and feeder OSP enter the cabinet at the floor of the rear compartment. The installer clamps the cable and breaks out
the fiber into 3-mm, radius-control (limited bend) loose tubing. The installer anchors feeder and distribution tubes along the cabinet’s
side wall and rear door.The tubes are guided to the top of the optional splice box located on the door.
The optional in-cabinet Telect Splice Box (Model MDC-SPLC) holds three pods of splice cassettes surrounded by a runway for the
loose tubing.