Types
Functions
Supply voltage
Part Nr. (PQ 1)
Part Nr. (PQ 10)
E1ZI10 12-240V AC/DC
Ip, Ii
12-240V AC/DC
110101
The output relay is triggered at the ratio of t1:t2 until the supply voltage
is interrupted.
A1 B1
15
A
21618
A
1
R
15
16
18
A2
U
~
(+)
(-)
E1ZI10
Functions
Asymmetric asher pause rst (Ip)
When the supply voltage U is applied, the set interval t1 begins (green
LED U/t ashes slowly). After the interval t1 has expired, the output
relay R switches into on-position (yellow LED illuminated) and the set
interval t2 begins (green LED U/t ashes fast). After the interval t2 has
expired, the output relay switches into off-position (yellow LED not
illumninated).
Asymmetric asher pulse rst (Ii)
When the supply voltage U is applied, the output relay R switches
into on-position (yellow LED illuminated) and the set interval t1 begins
(green LED U/t ashes slowly). After the interval t1 has expired, the
output relay switches into off-position (yellow LED not illuminated) and
the set interval t2 begins (green LED U/t ashes fast). After the interval
t2 has expired, the output relay switches into on-position (yellow LED
illuminated).
Connections
Ordering informations
The output relay is triggered at the ratio of t1:t2 until the supply voltage
is interrupted.