manual

bintec W2004n
04.12.2013
Subject to technical alterations
Page 8 / 9
Teldat GmbH - Suedwestpark 94 - 90449 Nuremberg - Germany
Phone: +49 - 911 9673-0 - Telefax: +49 - 911 688 07 25
E-Mail: info@teldat.de - www.teldat.org
Security
Inter cell repeating Inter traffic blocking for public HotSpot (PHS) applications for preventing of communication radio
client to radio client in a single radio cell.
NAT/PAT Network & Port Address Translation / Stateful Packet Inspection: Isolation of complete network from
public access
Energy Savining Functions
Mimo 1x1 shift down The radio modules switching automatic to Mimo 1x1 operation, when no client is connected
802.3az support The ethernet interfaces reduce the power consumption automatically, in case that no device is
connected. In the case of the usage of a short ethernet cable, the circuit reduce the transmit
power.
LED Mode The LEDs has three operation mode: Status, Flashing, Off
Maintenance
Configuration a. maintenance:
Configuration a. maintenance:
Device configuration via
Telnet, SSH, HTTP, HTTPS, SNMP
Configuration a. maintenance:
SNMP
SNMP (v1, v2, v3), USM model, VACM views, SNMP traps (v1, v2, v3) configurable, SNMP IP access
list configurable
Configuration a. maintenance:
SNMP configuration
Complete management with MIB-II, MIB 802.11, enterprise MIB
Configuration a. maintenance:
SSH Login
Supports SSH V1.5 and SSH V2.0, for secure connections of terminal applications
Configuration a. maintenance:
HTTP/HTTPS
Web-based configuration (FCI). The user interface is identical with almost all bintec elmeg
products.
Configuration a. maintenance:
Secure configuration
SSH available, HTTPS, Telnet protected against 'bruce force attacks'
Configuration a. maintenance:
Configuration export and import
Load and save of configurations; save configuration optionally encrypted; optional, automatic
controlled via scheduler
Configuration a. maintenance:
On the fly configuration
No restart is required after the configuration has been changed.
Configuration a. maintenance:
Software update
Software updates free of charge; loadable via file, HTTP or via direct access to the bintec elmeg
upload server; optional, automatic controlled via scheduler
External Reporting:
External reporting: Syslog Syslog client, with different levels of messaging
External reporting: eMail alert Automatic eMail alert by definable events (predefined events: new neighbor AP found, new rogue
AP found, new slave AP found, managed AP failed)
External reporting: SNMP traps Supported
Monitoring:
Monitoring: Internal Log Output via web-based configuration interface (http/https); filter: subsystem, level, message