(3) Power connection
Connect the device to a mains socket.
Use the power cord supplied and insert it in the appropriate socket on your device.
Now plug the power cord into a power socket (100–240 V). The status LEDs signal
that your device is correctly connected to the power supply. Optionally, power can
be supplied through a standard PoE injector (part number 5530000082).
Note
bintec WIx040n series products are supplied without a mains unit. All devices must be
earthed.
Note
To restrict power in the event of a fault, the 24 V DC electric circuit is to be protected
with an external 2 A fuse on the installation side for bintec WIx040n. The relay contact
must also be protected externally with a 1-A fuse (AC) or 2-A fuse (DC).
You can set up further connections as required:
Serial connection: For alternative configuration possibilities, connect the serial interface
of your PC (COM1 or COM2) to the serial interface of the gateway (console). However,
configuration via the serial interface is not provided by default.
Installation
The access points can be either be used as tabletop units or can be wall mounted with
hangers integrated into the housing. Optionally, they can be mounted with a top hat rail.
Use as a table-top device
Attach the four self-adhesive feet on the bottom of the device. Place your device on a solid,
level base.
Wallmounting
To attach the bintec WIx040n series devices to the wall, use the brackets on the back of
the housing. Optional wall mounting with theft protection (part number 5020590400), and
DIN rail (part number 5000592600) is available.