User manual
Field Description
value "-, or "-, (default value).
Short Guard Interval Enable this function to reduce the guard interval (= time
between transmission of two data symbols) from 800 ns to 400
ns.
Short Retry Limit Not available for bintec W1003n, bintec W2003n, bintec
W2003n-ext and bintec W2004n.
Enter the maximum number of attempts to send a frame. This
value must be less than or equal to the value specified in RTS
Threshold. After this many failed attempts, the packet is dis-
carded.
Possible values are to .
The default value is C.
Long Retry Limit Not available for bintec W1003n, bintec W2003n, bintec
W2003n-ext and bintec W2004n.
Enter the maximum number of attempts to send a data packet.
This value must be longer than the value specified in RTS
Threshold. After this many failed attempts, the packet is dis-
carded.
Possible values are to .
The default value is '.
Fragmentation
Threshold
Enter the maximum size as of which the data packets are to be
fragmented (i.e. split into smaller units). Low values are recom-
mended for this field in areas with poor reception and in the
event of radio interference.
Possible values are to ('.
The default value is (' bytes.
If " ) is selected for Operation Mode with Client Mode 6,
the following parameters are additionally available under Advanced Settings:
10 Wireless LAN Teldat GmbH
158 bintec WLAN and Industrial WLAN