Field Description
You can delete entries with the icon.
Beacon Period Only for Operation Mode = " ! or " )#
with Client Mode " ;.
Not available for bintec W1003n, bintec W2003n, bintec
W2003n-ext and bintec W2004n.
Enter the time in milliseconds between the sending of two
beacons.
This value is transmitted in Beacon and Probe Response
Frames.
Possible values are to (.
The default value is ms.
DTIM Period Only for Operation Mode = " ! or " )#
with Client Mode " ;.
Not available for bintec W1003n, bintec W2003n, bintec
W2003n-ext and bintec W2004n.
Enter the interval for the Delivery Traffic Indication Message
(DTIM).
The DTIM field is a data field in transmitted beacons that in-
forms clients about the window to the next broadcast or multic-
ast transmission. If clients operate in power save mode, they
come alive at the right time and receive the data.
Possible values are to .
The default value is .
RTS Threshold Here, you select how the RTS/CTS mechanism is to be
switched on/off.
If you choose +#, you can specify in the input field
the data packet length threshold in bytes (1 - 2346) as of which
the RTS/CTS mechanism is to be used. This makes sense if
several clients that are not in each other's wireless range are
run in one access point. The mechanism can also be switched
on/off independently of the data packet length by selecting the