Installation guide
bintec RXL12100
04.12.2013
Subject to technical alterations
Page 8 / 11
Teldat GmbH - Suedwestpark 94 - 90449 Nuremberg - Germany
Phone: +49 - 911 9673-0 - Telefax: +49 - 911 688 07 25
E-Mail: info@teldat.de - www.teldat.org
Logging / Monitoring / Reporting
SNMP traps SNMP traps (v1, v2, v3) configurable
Activity Monitor Sending of information to a PC on which Brickware is installed
IPSec monitoring Display of IPSec tunnel and IPSec statistic; output via web-based configuration user interface
(http/https)
Interfaces monitoring Statistic information of all pysical and logical interfaces (ETH0, ETH1, SSIDx, ...), output via
web-based configuration user interface (http/https)
ISDN monitoring Display of active and past ISDN connections; output via web-based configuration user interface
(http/https)
IP accounting Detailed IP accounting, source, destination, port, interface and packet/bytes counter, transmission
also via syslog protocol to syslog server
ISDN accounting Detailed ongoing recording of ISDN connection parameter like calling number and charging
information, transmission also via syslog protocol to syslog server
RADIUS accounting RADIUS accounting for PPP, PPTP, PPPoE and ISDN dialup connections
Keep Alive Monitoring Control of hosts/connections via ICMP polling
Tracing Detailed traces can be done for different protocols e.g. ISDN, PPPoE, ... generation local on the
device and remote via DIME Manager
Tracing Traces can be stored in PCAP format, so that import to different open source trace tools (e.g.
wireshark) is possible.
Administration / Management
RADIUS Central check of access authorization at one or several RADIUS server, RADIUS (PPP, IPSec
inclusive X-Auth and login authentication)
RADIUS dialout On a RADIUS server configured PPP und IPSec connection can be loaded into the gateway (RADIUS
dialout).
TACACS+ Support of TACACS+ server for login authentication and for shell comando authorization
Time synchronization The device system time can be obtained via ISDN and from a SNTP server (up to 3 time server
configurable). The obtained time can also be transmitted per SNTP to SNTP clients.
Automatic Time Settings Time zone profiles are configurable. That enables an automatic change from summer to winter
time.
Supported management
systems
DIME Manager, XAdmin
Configurable scheduler Configuring of time and event controlled tasks, e.g. reboot device, activate/deactivate interface,
activate/deactivate WLAN, trigger SW update and configuration backup
Configuration Interface (FCI) Integrated web server for web-based configuration via HTTP or HTTPS (supporting self created
certificates). This user interface is by most of bintec elmeg GmbH products identical.
Software update Software updates are free of charge; update via local files, HTTP, TFTP or via direct access to the
bintec elmeg web server
Remote maintenance Remote maintenance via telnet, SSL, SSH, HTTP, HTTPS and SNMP (V1,V2,V3)