3.7 POWER AND ANTTENUATION SWITCH SETTINGS
Figure 4 RPT700 Dual Band Front Panel
For the RPT700 Dual Band Repeater open the door on the Repeater and you will see three modules with a
row of switches on each module
The left side Module is marked “Uplink to Cell Tower” and below that is a frequency range. This module
controls the power level that will be transmitted back to the cellular tower for the stated frequency range.
The middle module is marked “Downlink to Area Fill” and below that is a frequency range. This module
controls the power level to the area you want covered by cell phone signal.
The right side Module is also marked “Uplink to Cell Tower” and below that is a different frequency
range. This module controls the power level that will be transmitted back to the cellular tower for the
stated frequency range.