 2-7 RLL: 2-item patterns are made up of 4 data items, 3-items pattern are
made up of 6 data items and 4-item patterns are made up of 8 data items.
Here the output data is inverted every time when 1 appears in the codes.
Pattern
Code
Conversion
 
 
 
 
 
 
 
Example
         
        
         
 user defined: When user defined has been selected as the code for pattern
setting from the Code selection menu, the following pattern systems can be
created by setting the values for Source Data Pattern, Converted Code,
Initial Src, Initial Code and Out[1/0].
NRZ
Initial Src 0
Initial Code 0
Out[1/0] High/Low
Source Data
Pattern
Converted Code
 
 