User's Manual
Appendix C: Performance Verification
AWG2021 User Manual
b. Set oscilloscope controls:
Vertical CH1. . . . . . . . . . . . . . . . . . . . . . . . . 
CH1 Coupling DC. . . . . . . . . . . . . . . . 
CH1 Scale 200 mV/div.. . . . . . . . . . . . . . . . . . . 
CH1 Input Impedance 50 W. . . . . . . . . . 
Horizontal
Sweep 50 ns/div.. . . . . . . . . . . . . . . . . . . . . . . 
Trigger
Source CH1. . . . . . . . . . . . . . . . . . . . . . 
Coupling DC. . . . . . . . . . . . . . . . . . . . . 
Slope Positive. . . . . . . . . . . . . . . . . . . . . . . 
Level 500 mV. . . . . . . . . . . . . . . . . . . . . . . 
Mode Auto. . . . . . . . . . . . . . . . . . . . . . . 
2. Set the AWG2021 controls and select the waveform file:
a. Initialize AWG2021 controls: Push UTILITYMiscConfig...Re-
set to FactoryO.K.
b. Select waveform file:
 Push SETUPWaveform Sequence, if necessary, to select a
waveform file for CH1. Waveform Sequence toggles between the
CH1 files (upper list) and the CH2 files (lower list).
 Turn the general purpose knob to highlight the SYNC_MRK.WFM
file.
 Push ENTER.
3. Check front-panel SYNC Out and MARKER Out amplitude:
a. Check SYNC Out pulse amplitude: Check that the pulse amplitude of the
waveform displayed on the oscilloscope is 1.2 V
p-p
 or greater.
b. Check CH1 MARKER 1 Out pulse amplitude:
 Move the coaxial cable from the AWG2021 CH1 SYNC Out
connector to the CH1 MARKER 1 connector.
 Change the oscilloscope sweep to 5 ms/div.
 Check that the pulse amplitude of the displayed waveform is from
2.250 V
p-p
 to 2.625 V
p-p
.