User's Manual

SimPal-S460 User Manual
22
3.5 Delay control the socket output
Description
The socket output can be set to delay switch ON/OFF for a period time.
Delay control function will auto deactivate once manual change socket status by
sending SMS or M button, activate Schedule control or Temperature control will also
stop the delay control function.
When the “delayed switch on the socket” command is received and if the socket output
is ON, the socket output will be switched off immediately and be switch on again when
the setting delayed time is reaching. Contrarily, if the socket output is OFF, the output
will remain switching off and turn ON when setting delay time is reach.
Method
Master sends following SMS message in order to:
Delay switching on after a certain minutes: #12#0#Minutes#1# (9)
Delay switching off after a certain minutes: #12#0#Minutes#0# (10)