SimPal-S460 User Manual SimPal-S460 4G LTE Power Socket Thank you for purchasing the SimPal-S460 power socket. SimPal-S460 working with 4G LTE SIM card, is a simple and powerful device to remote control the power to the electrical devices or electrical outlets at home via SMS or app in mobile. SimPal-S460 supports power meter function and power loading monitor, can be used to monitor connected device working status. It will send SMS when connected device power consumption abnormal.
SimPal-S460 User Manual For your safety......................................................................................................................... 5 Exception clause...................................................................................................................... 7 1.1 Package contents............................................................................................................ 11 1.2 Sockets instructions.......................................................
SimPal-S460 User Manual 3.6 Schedule control..............................................................................................................23 3.7 Temperature control........................................................................................................ 26 3.8 Temperature alarm..........................................................................................................28 3.9 Power loading alarm.......................................................................
SimPal-S460 User Manual 1. Purchase a GSM SIM card (mobile phone card) from GSM network service provider and install it in the socket. This SIM card number is referred as SimPal-S460 number on this brochure. 2. The user needs to activate the Caller ID Presentation function of SIM card, and deactivate PIN code of the SIM. Contact with GSM network service provider for support.
SimPal-S460 User Manual For your safety This socket was designed for home or office use. Do not use it on the electrical appliance which is for industry or business operation, for example, iatrical appliances, large heaters and refrigerates. Before using this socket, make sure that the mobile phones can be used well in the area, otherwise, do not put this socket into operation. The power consumption of the appliances connected with the socket cannot exceed 3500W and the current cannot exceed 16A.
SimPal-S460 User Manual Do not plug this socket in a row, only allow connect other electricity device on the socket. (nicht hintereinander stecken, nur andere Stromgeräte an der Steckdose anschließen lassen). Do not open the case unless maintenance needed. Do not keep shaking or fall down this socket, otherwise it can be damaged. This socket is a wireless signal transmission socket. Keep it away from electronic equipment likely to interfere with the wireless signals, in order to avoid signals interference.
SimPal-S460 User Manual FCC Radiation Exposure Statement: This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with minimum distance 20cm between the radiator & your body. FCC Warning This device complies with Part 15 of the FCC Rules.
SimPal-S460 User Manual NOTE 1: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications.
SimPal-S460 User Manual - Increase the separation between the equipment and receiver. -Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. -Consult the dealer or an experienced radio/TV technician for help. NOTE 2: Any changes or modifications to this unit not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment.
SimPal-S460 User Manual Exception clause 1. We operate on a policy of continuous development. We reserve the right to make changes and improvements to any of the sockets described in this document without prior notice. 2. For the latest socket information, please visit: http://www.simpal.cn. We don’t guarantee for the document veracity, reliability or any content except regulate in proper laws. Including no guarantee for socket suitable market or suitable area promise. 3.
SimPal-S460 User Manual 1.
SimPal-S460 User Manual 1.
SimPal-S460 User Manual 13
SimPal-S460 User Manual 1.3 Light indicator Indicator Action Status Turn off Socket power output OFF Constant light Socket power output ON Flash slowly Searching network Slowly breath Working in standby mode.
SimPal-S460 User Manual 2.1 User authorization level Socket settings can be set or adjusted via a SMS command. There are two mobile phone user controlling levels: Master-user (“Master”): Only one Master has authorization to use all features of SimPal-S460. In order to enable all the functions on the socket, the Master must store his/ her mobile number in the socket’s memory. Only one Master’s mobile number is allowed for a socket.
SimPal-S460 User Manual 2.2 About the SMS Command • SMS command format: #code#content#. • The maximum digits that are allows for the phone number is sixteen. • SimPal-S460 will reply to the user after it receives the SMS command. ֠ Note • The “#” symbol must not be ignored when typing an SMS command. • No allow any space within the commands. 3.
SimPal-S460 User Manual Insert the temperature sensor into the I/O port until it is seized. Power on: 1. Plug the SimPal-S460 in an AC power socket. The GSM LED will be flashing slowly for about 15 seconds, and turn to slowly breathe status, breathe LED means the socket already register GSM network, its ready to working. The socket default power output is OFF. 2. Insert the plug of electronic appliance in the SimPal-S460 electrical outlet. 3.
SimPal-S460 User Manual 2. Check GSM network signal of the using place: • GSM network’s signal strength may affect the socket feature. Therefore, before using, the user should ensure that SimPal-S460 is used in an area with a strong GSM network signal. • For the first time use, the user should perform a test-run by sending SMS to the socket. This allows the user to check the GSM network connection of the socket. 3.
SimPal-S460 User Manual Even without APP, user can send SMS manually according following instruction to control the socket. 3.3 Register Master-number. Sending following SMS to socket SIM card number from your mobile phone (the phone number will be the Master number): Register Master-number on the socket: #00# (1) 3.3.1 Change Master number Master sends following SMS message in order to: Change master-number: #14#NewMasterNumber • NewMasterNumber should be the new Master mobile phone number.
SimPal-S460 User Manual 3.3.2 Register User-number Max allow to register 4 User numbers on one device. User-number have the authority to control the socket. Method Master sends following SMS message in order to: Register a User: #06#User-Number# (3) • User-Number should be the User’s mobile phone number. Suggest to add country code in front of phone number. Such as #06#+4912345678# 3.3.
SimPal-S460 User Manual 3.3.3 Delete User Method Master sends following SMS message in order to: Delete a User number: #15#User-Number # Delete all Users: #15# (5) (6) 3.4 Turn on/off power Method Method 1:To press M button one second (See 5 on Figure1).
SimPal-S460 User Manual 3.5 Delay control the socket output Description The socket output can be set to delay switch ON/OFF for a period time. Delay control function will auto deactivate once manual change socket status by sending SMS or M button, activate Schedule control or Temperature control will also stop the delay control function.
SimPal-S460 User Manual Minutes are time parameters, range is 1-720. 3.6 Schedule control 3.6.1 Activate schedule control Description The socket can be set three group schedule to auto turn on off according time schedule. Schedule control function will temporary deactivate if user manually change the socket status by SMS or press M button, it will process schedule control when time reach next action point.
SimPal-S460 User Manual Socket will auto switching on or off the output according to the schedule settings. 3.6.2 Set schedule Description After successful setting of time duration to switch on the socket output, the schedule parameter will be saved on the socket until socket reset to factory settings.
SimPal-S460 User Manual single days, it needs to combined day number. Such as 1234, means from Monday-Thursday; 15 means Monday and Friday. The following table contains the descriptions of each value: Value 0 1 2 3 4 5 6 7 Corresponding day Everyday Monday Tuesday Wednesday Thursday Friday Saturday Sunday StartTime and EndTime: Be consists of 4 digits (hh:mm) and works on a 24 hour clock. If StartTime bigger than EndTime, it will operate until next day EndTime.
SimPal-S460 User Manual For example: #20#0#2#13#0000#2130#, set group 2 schedule control, Monday and Wednesday, turn on power from 00:00 and turn off at 21:30. Turn off schedule control function: #19#0#0# (13) 3.7 Temperature control 3.7.1 Activate temperature control function Description The external temperature sensor must be inserted into the I/O port of socket. The socket power output can be auto controlled according environment temperature change.
SimPal-S460 User Manual warming mode, socket will auto turn on when temperature lower than smaller temperature value, and turn off when higher than bigger temperature value; Cooling mode, socket will auto turn on when temperature higher than bigger temperature value and turn off when temperature lower than smaller value. Method The Master sends following SMS message in order to: Turn on temperature control: #23#0#1# (14) 3.7.
SimPal-S460 User Manual Temp range should be within -10 to 50 degree. For example #24#0#1#15#25#, it means set SimPa-S460 temperature control parameter, work with warming mode, and turn on socket when temperature lower than 15 degree, turn off socket when temperature higher than 25 degree. After successful setting of temperature range, the temperature parameter will be saved on the socket until socket reset to factory settings. Turn off temperature control: #23#0#0# (16) 3.
SimPal-S460 User Manual will auto-send the SMS alarm message to your mobile phone. This feature depends on the temperature sensor. Method Master sends following SMS message in order to: Set temperature alarm - ON: #21#0#1# (17) Set temperature range: (18) #22#0#MinTemp#MaxTemp# MinTemp and MaxTemp: The values can be set within the range of -10 to 50 centigrade degree.
SimPal-S460 User Manual 3.9 Power loading alarm Description The socket support power loading alarm function. It can monitor connected appliances power consumption and report power consumption daily, weekly or monthly.
SimPal-S460 User Manual Set power loading range: #53#0#MinValue#MaxValue# (25) MinValue and MaxValue: The values can be set within the range of 0 to 3500, means 0-3500W. Default value is 5-3500. The power alarm is executed only when the power is turned on. When the power is turned off, the power is always zero, it does not send alarm message. After the power is turned on, it will compare the power before the power is turned off. If the two powers are in the same range, no SMS alarm will be sent.
SimPal-S460 User Manual The power consumption data will lost when device reboot, it will new calculate from beginning when socket power restore. 3.10 SMS when on/off button pressed Description SimPal-S460 will default sending SMS notify Master and Users when press M button to change power status. It can send SMS to enable/disable this SMS notification.
SimPal-S460 User Manual 3.11 Power failure alarm Description SimPal-S460 will default sending SMS notify when main power supply lost or restore. It can send SMS to enable/disable this SMS notification. Method Master sends following SMS message in order to set: SMS when power lost or restore - ON (Default): #05#1# (33) SMS when power lost or restore - OFF: #05#0# (34) 3.12 SMS notification to User SimPal-S460 will sending SMS alert when mains power lost/restore, temperature alert or other information.
SimPal-S460 User Manual Method Master sends following SMS message in order to: SMS to Master and all Users: #16#1# SMS only to Master number: #16#0# (35) (36) 3.13 Calling control settings Master and user number default allow calling SimPal-S460 to switch power output, default without SMS reply when calling switch power.
SimPal-S460 User Manual Any number calling control – OFF (Default): #31#0# (42) 3.
SimPal-S460 User Manual ( 4 Check “Schedule control” parameters: 4 #33# Check “Temperature control” parameters: Check “Temperature alarm” parameters: ) (45) #32# #35#0# (46) (47) 3.15 Weak GSM signal notification The socket can send a SMS notification when the GSM signal strength is too weak. The Master user can enable/disable this SMS notification.
SimPal-S460 User Manual ( • 5 Successful SMS reply Operator: Name Network type: LTE CSQ: 20 Weak GSM signal alarm: ON 0 ) The alerter will send SMS message when it alarms: Weak GSM signal alert, the CSQ is **. 3.16 Resetting the socket Description This function resets all programmed settings to their original values, including cleaning all user number, timing parameter and temperature parameter.
SimPal-S460 User Manual If the setting status is wrong or the malfunctions can’t be corrected, users can restore the socket to its original status to make it work normally. SimPal-S460 reset factory setting: Method 1: Press the side M button of the device for 10 seconds.
SimPal-S460 User Manual 4.
SimPal-S460 User Manual Appendix: SMS commands list Category Function Register Master-number Change Master-number Define the users Add User-number Check User-number Delete User-number Delete all User-number Manual change socket output Delay control Command (1) #00# (2) #14#NewMasterNumber# (3) #06#User-Number# (4) #06# (5) #15#User-Number# (6) #15# Turn on power (7) #01#0# Turn off power (8) #02#0# Delay switching ON after a certain minutes 40 (9) #12#0#Minutes#1#
SimPal-S460 User Manual Category Function Delay switching OFF after a certain minutes Calendar control Temperature control Temperature alarm Command (10) #12#0#Minutes#0# Schedule control function - OFF (11) #19#0#1# Set schedule control parameters (12) #20#0#ID#WorkDay# StartTime#EndTime# Schedule control function - OFF (13) #19#0#0# Temperature control function - ON (14) #23#0#1# Set temp control parameters (15) #24#0#mode#low-temp#high-t emp# Temperature control function - OFF (16) #23#0
SimPal-S460 User Manual Category Power meter Function Command Temperature alarm function - OFF (19) #21#0#0# Check voltage and power loading (20) #51# Check yesterday power consumption (21) #52#1# Check this week power consumption (22) #52#2# Check this month power consumption (23) #52#3# Power loading alarm - ON Set power loading range Power loading alarm - OFF (Default) (24) #53#0#1# (25) #53#0#Low#High# (26) #53#0#0# Daily report power consumption (27) #54#1# Weekly report power consump
SimPal-S460 User Manual Category SMS notification Calling control Function Command Report power consumption - OFF (30) #54#0# SMS when press button – OFF (Default) (31) #03#1# SMS when press button - OFF (32) #03#0# SMS when power lost - ON (Default) (33) #05#1# SMS when power lost - OFF (34) #05#0# SMS to User number – ON (Default) (35) #16#1# SMS to User number - OFF (36) #16#0# Calling control function – ON (Default) (37) #09#1# Calling control function – OFF (38) #09#0# SMS when c
SimPal-S460 User Manual Category Function (41) #31#1# Any number calling control – OFF (Default) (42) #31#0# Check socket status Check status (43) #07# Check S “Delayed Control” status (44) #34# Check “Schedule control” status (45) #33# Check “Temp control” status (46) #32# Check “temp alarm” status Check GSM signal and network type Reset socket Command Any number calling control – ON (47) #35#0# (48) #27# Weak GSM signal alarm - ON (49) #27#1# Weak GSM signal alarm – OFF (Default) (50