SimPal-T420 4G Power Socket SimPal-T20 Wireless Power Socket User Manual Version 3.
SimPal-T420/T20 USER MANUAL SimPal-T420/T20 Power Socket Thank you for purchasing the SimPal-T420/T20. SimPal-T420 4G power socket is a remote-controlled socket consisting of a 4G LTE module. The power supply output can be turned on or off remotely by SMS command or voice calling. SimPal-T420 Master socket can be connect up to 4pcs SimPal-T20 slave socket and 6pcs wireless sensor.
SimPal-T420/T20 USER MANUAL For your safety ......................................................................................7 Exception clause ................................................................................. 11 1.1 Package contents...........................................................................12 1.2 Sockets instructions .......................................................................13 1.3 Light indicator ............................................................
SimPal-T420/T20 USER MANUAL 2.2 About the SMS Command..............................................................17 3.1 Start to use ....................................................................................17 3.2 Download “LTE Socket” APP ......................................................20 3.3 Register Master-number. ...............................................................20 3.4 Pairing slave socket ......................................................................22 3.
SimPal-T420/T20 USER MANUAL 3.7 Schedule control ............................................................................27 3.8 Temperature control ......................................................................30 3.9 Temperature alarm ........................................................................33 3.10 Connect wireless sensor ..............................................................34 3.11 SMS when on/off button pressed ..................................................37 3.
SimPal-T420/T20 USER MANUAL 3.14 SMS notification to User .............................................................39 3.15 Check status ................................................................................39 3.16 Weak LTE signal alarm ...............................................................41 4. Reset factory setting ........................................................................42 5. Main Technical Parameters ............................................................
SimPal-T420/T20 USER MANUAL 1. Purchase a LTE SIM card (mobile phone card) from LTE network service provider and install it in the socket. This SIM card number is referred as SimPal-T420 number on this brochure. 2. The user needs to activate the Caller ID Presentation function of SIM card, and deactivate PIN code of the SIM. Contact with LTE network service provider for support.
SimPal-T420/T20 USER MANUAL For your safety This socket was designed for home or office use. Do not use it on the electrical appliance which is for industry or business operation, for example, Industrial appliances, large heaters and refrigerates. Before using this socket, make sure that the mobile phones can be used well in the area, otherwise, do not put this socket into operation.
SimPal-T420/T20 USER MANUAL Do not plug this socket in a row, only allow connect other electricity device on the socket. (nicht hintereinander stecken, nur andere Stromgeräte an der Steckdose anschließen lassen). Do not open the case unless maintenance needed by professionals. Do not keep shaking or fall down this socket, otherwise it can be damaged. This socket is a wireless signal transmission socket.
SimPal-T420/T20 USER MANUAL FCC Radiation Exposure Statement: This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with minimum distance 20cm between the radiator & your body. FCC Warning This device complies with Part 15 of the FCC Rules.
SimPal-T420/T20 USER MANUAL used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: - Reorient or relocate the receiving antenna.
SimPal-T420/T20 USER MANUAL Exception clause 1. We operate on a policy of continuous development. We reserve the right to make changes and improvements to any of the sockets described in this document without prior notice. 2. For the latest socket information, please visit: http://www.simpal.cn. We don’t guarantee for the document veracity, reliability or any content except regulate in proper laws. Including no guarantee for socket suitable market or suitable area promise. 3.
SimPal-T420/T20 USER MANUAL 1.
SimPal-T420/T20 USER MANUAL 1.
SimPal-T420/T20 USER MANUAL Figure 2: Temperature sensor Instruction 14
SimPal-T420/T20 USER MANUAL 1.3 Light indicator Model Indicator Action Status Turn off Socket power output OFF Turn on Socket power output ON Power Indicator Slowly breath Searching network (SimPal-T420) Lost connection with T420 (SimPal-T20) Working in standby mode. Two fast and one slow Flash Pairing slave socket or pairing wireless sensor status.
SimPal-T420/T20 USER MANUAL 2.1 User authorization level Socket settings can be set or adjusted via a SMS command. There are two mobile phone user controlling levels: Master-user (“Master”): Only one Master has authorization to use all features of SimPal-T420. Master number has the authorization to use all functions of this socket. Only one Master’s mobile number is allowed for a socket.
SimPal-T420/T20 USER MANUAL 2.2 About the SMS Command SMS command format: #code#content#. The maximum digits that are allows for the phone number is sixteen. SimPal-T420 will reply to the user after it receives the SMS command. Note The “#” symbol must not be ignored when typing an SMS command. No allow any space within the commands. 3.
SimPal-T420/T20 USER MANUAL Insert the temperature sensor into the I/O port until it is seized. Power on: 1. Plug the SimPal-T420 in an AC power socket. The indicator will be flashing slowly for about 15 seconds, then long beep ring and turn to slowly breathe status, breathe indicator means the socket already register LTE network, its ready to working. The socket default power output is OFF. 2. Insert the plug of electronic appliance in the SimPal-T420 electrical outlet.
SimPal-T420/T20 USER MANUAL 3. M button (See 5 on Figure1) can be pressed for about one second to switch on or off the socket output. After adding user numbers to the socket, users can send SMS command or make calling to control the power supply output. Note: 1. If the wireless indicator light is flash slowly all the time, which imply the SIM card working abnormally, all functions of this socket are invalid. 2.
SimPal-T420/T20 USER MANUAL 3.2 Download “LTE Socket” APP We offer free APP to work with SimPal-T420, search “LTE Socket” on Google Play or Apple APP Store, download and install the APP, then it can use APP to control SimPal-T420. First time register device on APP, input device name and SIM card number which installed on SimPal-T420 device. The APP will create SMS content, send the SMS to device, it will operate according APP function description.
SimPal-T420/T20 USER MANUAL 3.3.1 Change Master number Master sends following SMS message in order to: Change master-number: #14#NewMasterNumber NewMasterNumber should be the new Master mobile phone number. (2) 3.3.2 Register Family-number Max 4 Family-number can be stored on each socket. Family-number have the authority to send SMS command to on/off power, set auto control and receive alarm messages.
SimPal-T420/T20 USER MANUAL code in front of phone number, such as +4912345678. Check Family number: Master sending SMS to check Family number: #06# (4) Delete Family Method Master sends following SMS message in order to: Delete a Family: #15#Family-Number # Delete all Family numbers: #15# (5) (6) 3.
SimPal-T420/T20 USER MANUAL before paring, need to make sure T20 reset factory setting, if the T20 already paired with other T420 before, need to keep press T20 M button for 10 seconds to reset factory setting. Master send following SMS message in order to: Pairing Slave socket: #60#name# (7) After receive SMS reply “Power on “name” socket now!”, plug the T20 socket to main power, T20 LED flash slowly for some seconds and go to slowly breath status after connected with T420 socket.
SimPal-T420/T20 USER MANUAL Remove slave socket: #71#name# Remove all slave socket: #71# (8) (9) 3.5 Turn on/off power Method Method 1:To press M button one second (See 5 on Figure1).
SimPal-T420/T20 USER MANUAL Slave socket power - OFF: #62#name# Master socket and all Slave socket power – OFF: #02# (14) (15) 3.6 Delay control Description The socket output can be set to delay switch ON/OFF for a period time. Delay control function will auto deactivate once manual change socket status by sending SMS or M button, activate schedule control or temperature control will also deactivate the delay control function.
SimPal-T420/T20 USER MANUAL #12#0#Minutes#1# Slave socket turn OFF now and turn ON after certain minutes: #63#name#Minutes#1# (16) (17) Master socket turn ON now and turn OFF after certain minutes: #12#0#Minutes#0# (18) Slave socket turn ON now and turn OFF after certain minutes: #63#name#Minutes#0# (19) Minutes are time parameters, its range is 1-720, Set Master socket delay control – OFF: #11#0# Set Slave socket delay control – OFF: #63#name#0# 26 (20) (21)
SimPal-T420/T20 USER MANUAL 3.7 Schedule control 3.7.1 Activate schedule control Description The socket power can be set to automatically turn on according schedule. Schedule control function will auto deactivate if user manually change the socket status by SMS or M button, Delay control will also deactivate schedule control function. But temperature control and schedule control can be working at the same time, it do not process temperature control during schedule turn off power.
SimPal-T420/T20 USER MANUAL Socket will auto switching on or off the output according to the schedule settings. 3.7.2 Set schedule parameters Description After successful setting of time duration to switch on the socket output, the schedule parameter will be saved on the socket.
SimPal-T420/T20 USER MANUAL WorkDay: one digit, the values lie in the range of “0” to “8”. The following table contains the descriptions of each value: Value 0 1 2 3 4 5 6 7 8 9 Corresponding day Everyday Monday Tuesday Wednesday Thursday Friday Saturday Sunday Monday to Friday Weekend StartTime and EndTime: Be consists of 4 digits (hh:mm) and works on a 24 hour clock. If StartTime bigger than EndTime, it will operate until next day EndTime.
SimPal-T420/T20 USER MANUAL For example: #20#0#1#1200#0800# , 0 means the SimPal-T420, 1200 means time 12:00(hh:mm)AM, 0800 means time 08:00. It will turn on power at 12:00, and turn off at 08:00 of next day. 3.8 Temperature control 3.8.1 Activate temperature control Description The external temperature sensor must be inserted into the I/O port of socket. The socket power output can be auto controlled according environment temperature change.
SimPal-T420/T20 USER MANUAL mode, socket will auto turn on when temperature lower than smaller temperature value, and turn off when higher than bigger temperature value; Cooling mode, socket will auto turn on when temperature higher than bigger temperature value and turn off when temperature lower than smaller value.
SimPal-T420/T20 USER MANUAL Set Master socket temp control parameters: #24#0#mode#low-temp#high-temp# Set Slave socket temp control parameters: #67#name#mode#low-temp#high-temp# (32) (33) Mode parameter can be 1 or 2, Warming mode is 1, cooling mode is 2; Temperature range should be within -10 to 50 degree.
SimPal-T420/T20 USER MANUAL 3.9 Temperature alarm Description A range of temperature can be pre-set onto each socket. When surroundings temperature is detected out of the pre-set temperature range, the SimPal-T420 will auto-send the SMS alarm message to your mobile phone. This feature depends on the temperature sensor.
SimPal-T420/T20 USER MANUAL MinTemp and MaxTemp: The values can be set within the range of -10 to 50 centigrade degree. Master socket temperature alarm - OFF (Default) : #21#0#0# (38) Slave socket temperature alarm - OFF (Default): #68#name#0# (39) 3.10 Connect wireless sensor Description SimPal-T420 can be working with 6pcs wireless sensor and 2pcs remote control, it can use for alarm functions.
SimPal-T420/T20 USER MANUAL There are two types of alarm sensor, one is alarm type, only alarm when T420 alarm function on, the other one is emergency type, it will always alarm even T420 alarm function off. For smoke detector and water leak detector, suggest to pair as emergency type sensor.
SimPal-T420/T20 USER MANUAL Sensor name only can be English letter of digital number, can not set other characters as sensor name. Max allow 10 characters for sensor name. Set alarm function - ON: #40#1# Set alarm function - OFF: #40#0# Set schedule alarm function - ON: #47#1# Set schedule alarm function - OFF: #47#0# Set schedule alarm time period: #46#day#start-time#end-time# Schedule alarm parameter day time parameters is same as Schedule control.
SimPal-T420/T20 USER MANUAL 3.11 SMS when on/off button pressed Description SimPal-T420 will default sending SMS notify Master and Family when press M button to turn on/off power. The Master can enable/disable this SMS notification. Method Master sends following SMS message in order to set: SMS when on/off button pressed - ON (Default): #03#1# (54) SMS when on/off button pressed - ON: #03#0# (55) 3.
SimPal-T420/T20 USER MANUAL only alert when SimPal-T420 power supply change, SimPal-T20 power supply change will not report. Master can enable/disable this SMS notification. Method Master sends following SMS message in order to set: SMS when power lost or restore - ON (Default): #05#1# (56) SMS when power lost or restore - OFF: #05#0# (57) 3.
SimPal-T420/T20 USER MANUAL Calling control function – ON(Default): #09#1# Calling control function – OFF: #09#0# (60) (61) 3.14 SMS notification to User SimPal-T420 will sending SMS alert when mains power lost/restore, temperature alert or other information. Default sending SMS to both Master and family. Master can change the setting only send SMS to Master number.
SimPal-T420/T20 USER MANUAL Master or Family sends following SMS message in order to: Check Master socket operating status: #07# Check Slave socket operating status: #70# After receiving the SMS commands, it will reply SMS message like this: Main unit: ON 23C “Slave1”: OFF 30C T “Slave2”: ON 23C S “Slave3”: ON 25C D “Slave4”: ON 25C D (64) (65) Socket under “delay control” it will show character “D” after the temperature value, when socket under “Temperature control”, it will show character “T” after the
SimPal-T420/T20 USER MANUAL Check Master socket “Schedule control” parameters: #33# Check Slave socket “Schedule control” parameters: #64#name# (68) (69) Check Master socket “Temperature control” parameters: Check Slave socket “Temperature control” parameters: (70) (71) #32# #66#name# Check Master socket “Temperature alarm” parameters: #35#0# Check Slave socket “Temperature alarm” parameters: #68#name# (72) (73) 3.
SimPal-T420/T20 USER MANUAL Check LTE signal #27# Weak LTE signal alarm - ON: #27#1# Weak LTE signal alarm - OFF (Default): #27#0# (74) (75) (76) The LTE signal is show as CSQ, CSQ range is 0-31, when CSQ lower than 13, it will set as weak LTE signal. When CSQ lower than 10, device will stop working. 4. Reset factory setting Description This function resets all programmed settings to their original values, including cleaning all user number, timing parameter and temperature parameter.
SimPal-T420/T20 USER MANUAL Master socket reset factory setting: Method 1: Keep press the side M button of the device for 10 seconds. Method 2: Master sends following SMS message in order to: Reset Master socket: #08#1234# SimPal-20 reset factory setting: Method : Keep press the M button of the device for 10 seconds. 5.
SimPal-T420/T20 USER MANUAL Relative humidity Communication protocols Data interface 10-90%,without condensation LTE PHASE 2/2+ (including data operation) LTE SIM 1.8V/3.
SimPal-T420/T20 USER MANUAL Appendix: SMS commands list Category Define the users Function Command Register Master-number (1) #00# Change Master-number (2) #14#NewMasterNumber# Add Family-number (4) #06# Delete Family-number (5) #15#Family-Number# Delete all Family-number Pairing T20 slave socket Power control (3) #06#Family-Number# Check Family-number (6) #15# Pairing slave socket (7) #60#name# Remove slave socket (8) #71#name# Remove all slave socket (9) #71# T420 socket power - ON
SimPal-T420/T20 USER MANUAL Category Function Command All socket power - ON Delay control T420 socket power - OFF (13) #02#0# T20 socket power - OFF (14) #62#name# All socket power - OFF Delay switching ON SimPal-T420 after a certain minutes Delay switching ON SimPal-T20 after a certain minutes Delay switching OFF SimPal-T420 after a certain minutes Delay switching OFF SimPal-T20 after a certain minutes T420 delay control – OFF (Default) T20 delay control – OFF (Default) Calendar (12) #01# T420
SimPal-T420/T20 USER MANUAL Category Function control T420 schedule control – OFF (Default) Temperature control Command (23) #19#0#0# T20 schedule control - ON (24) #64#name#1# T20 schedule control – OFF (Default) (25) #64#name#0# Set T420 schedule control parameters (26) #20#0#WorkDay# StartTime#EndTime# Set T20 schedule control parameters (27) #65#name#WorkDay#StartTim e#EndTime# T420 Temp control - ON (28) #23#0#1# T420 Temp control - OFF (Default) (29) #23#0#0# T20 Temp control - ON
SimPal-T420/T20 USER MANUAL Category Temperature alarm Wireless Function Command Set T420 temp control parameters (32) #24#0#mode#low-temp#high-te mp# Set T20 temp control parameters (33) #67#name#mode#low-temp#hig h-temp# T420 temperature alarm - ON (34) #21#0#1# T20 temperature alarm - ON (35) #68#name#1# Set SimPal-T420 temp range (36) #22#0#MinTemp#MaxTemp# Set SimPal-T20 temp range (37) #69#name#MinTemp#MaxTemp# T420 temperature alarm - OFF (Default) (38) #21#0#0# T20 temperature al
SimPal-T420/T20 USER MANUAL Category Function sensor alarm Pair emergency sensor Command Pair remote control Check sensor list Remove single sensor (41) #30#2#name# (42) #30#3# (43) #30# (44) #44#name# Remove all sensors (45) #44# Remove all remote control (46) #45# Alarm function – ON (47) #40#1# Alarm function – OFF (Default) (48) #40#0# Schedule alarm - ON (49) #47#1# Schedule alarm - OFF (Default) (50) #47#0# Set schedule alarm parameters Pair wireless siren 49 (51) #46#day#start-t
SimPal-T420/T20 USER MANUAL Category Function Command Set beeper duration SMS notification Calling control SMS to Users (53) #50#time# SMS when on/off button pressed - ON (Default) (54) #03#1# SMS when on/off button pressed - OFF (55) #03#0# SMS when power lost or restore – ON (Default) (56) #05#1# SMS when power lost or restore – OFF (57) #05#0# SMS when calling control – ON (Default) (58) #49#1# SMS when calling control – OFF (59) #49#0# Calling control function – ON (Default) (60) #
SimPal-T420/T20 USER MANUAL Category Check status Function Command Check T420 socket status (64) #07# Check T20 socket status (65) #70# Check T420 “Delayed Control” settings (66) #34# Check T20 “Delayed Control” settings (67) #63#name# Check T420 “Schedule control” settings (68) #33# Check T20 “Schedule control” settings (69) #64#name# Check T420 “Temp control” settings (70) #32# Check T20 “Temp control” settings (71) #66#name# Check T420 “Temp alarm” settings (72) #35#0# Check T20 “T
SimPal-T420/T20 USER MANUAL Category Function Command Check LTE signal Reset socket (74) #27# Weak LTE signal alarm – ON (75) #27#1# Weak LTE signal alarm – OFF (Default) (76) #27#0# Reset T420 to factory setting 52 (77) #08#1234#
SimPal-T420/T20 USER MANUAL FCC Radiation Exposure Statement: This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with minimum distance 20cm between the radiator & your body. FCC Warning This device complies with Part 15 of the FCC Rules.
SimPal-T420/T20 USER MANUAL NOTE 1: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications.
SimPal-T420/T20 USER MANUAL -Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. -Consult the dealer or an experienced radio/TV technician for help. NOTE 2: Any changes or modifications to this unit not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment.