User's Manual
Table Of Contents
- Title page
 - Table of Contents
 - General Safety Summary
 - Preface
 - Getting Started
 - Operating Basics
 - Reference
- Reference
 - Menu Structures
 - The Setup Menu Screen
 - The Graphical Waveform Editor
 - The Pattern Editor
 - Quick Editing
 - The Table Editor
 - The Equation Editor
 - The Sequence Editor
 - The APPL Menu
 - The UTILITY Window
- External Keyboards
 - Setting General Purpose Knob Direction
 - Formatting a Floppy Disk
 - Displaying Disk Usage
 - Screen Display Enable/Disable
 - Focused Color
 - Displaying Instrument Status
 - Internal Clock (Date and Time)
 - Resetting the Instrument
 - Connecting to a GPIB Network
 - Ethernet Networking
 - Hardcopy
 - Calibration and Diagnostics
 - Upgrading the System Software
 
 - Capturing Waveforms
 - Waveform Programming Language
 - Command Descriptions
 - Programming Examples
 - File Conversion
 - File Management
 - FG Mode
 - Waveform Mixing Mode
 - Synchronous Operation Mode (AWG710B only)
 
 - Appendices
- Appendix A: Specifications (AWG710B)
 - Appendix A: Specifications (AWG710)
 - Appendix B: Performance Verification (AWG710B)
- Conventions
 - Self Tests
 - Performance Tests
 - Operating Mode Tests
 - Amplitude and Offset Accuracy Tests (Normal Out), (except option 02)
 - Amplitude, Offset Accuracy and Rise Time Tests (Direct DA Out), (except option 02)
 - Amplitude, Offset Accuracy and Rise Time Tests (for option 02)
 - Pulse Response Tests (Normal Out), (except option 02)
 - Trigger Input Tests
 - Event Input and Enhanced Mode Tests
 - External Clock Input and VCO Out Output Tests
 - VCO OUT Output Frequency and 10 MHz Reference Input Tests
 - Marker Output Tests
 - Synchronous Operation Tests
 
 - Appendix B: Performance Verification (AWG710)
- Conventions
 - Self Tests
 - Performance Tests
 - Operating Mode Tests
 - Amplitude and Offset Accuracy Tests (Normal Out), (except option 02)
 - Amplitude, Offset Accuracy and Rise Time Tests (Direct DA Out), (except option 02)
 - Amplitude, Offset Accuracy and Rise Time Tests (for option 02)
 - Pulse Response Tests (Normal Out), (except option 02)
 - Trigger Input Tests
 - Event Input and Enhanced Mode Tests
 - 1/4 Clock Frequency and 10 MHz Reference Input Tests
 - Marker Output Tests
 
 - Appendix C: Inspection and Cleaning
 - Appendix D: Sample Waveforms
 - Appendix E: File Transfer Interface Outline
 - Appendix F: Miscellaneous
 - Appendix G: Sequence File Text Format
 
 - Index
 

Appendix B: Performance Verification (AWG710)
AWG710&AWG710B Arbitrary Waveform Generator User Manual B-85
Pulse Response Tests (Normal Out), (except option 02)
This procedure checks the pulse response characteristics of the AWG710 Arbitrary 
Waveform Generator output waveforms at amplitudes of 1 V. 
Do the following steps to install the test hookup and set the test equipment controls:
1. Use the 50 Ω SMA coaxial cable to connect the AWG710 Arbitrary Waveform 
Generator CH1 output connector to the oscilloscope CH1 input connector (see 
Figure B-48). 
Figure B-48: Pulse response initial test hookup
2. Set the oscilloscope controls as follows:
3. Push UTILITY (front–panel)!System (bottom)!Factory Reset (side) 
!OK (side).
Equipment 
required
A 50 Ω SMA coaxial cable and an oscilloscope (TDS820).
Prerequisites
The AWG710 Arbitrary Waveform Generator must meet the prerequisites 
listed on page B-61.
VerticalCH1
CH1 coupling. . . . . . . . . . . . . . . . . . . . . . . . . DC if applicable
CH1 scale . . . . . . . . . . . . . . . . . . . . . . . . . . . 200 mV/div
Horizontal
Sweep . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 500 ps/div
Trigger
Source. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . CH1
Slope . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Positive
Level . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 0 V
Mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Auto
AWG710 Arbitrary Waveform Generator Oscilloscope (TDS820)
50Ω SMA coaxial cable