User's Manual
Table Of Contents
- Title page
 - Table of Contents
 - General Safety Summary
 - Preface
 - Getting Started
 - Operating Basics
 - Reference
- Reference
 - Menu Structures
 - The Setup Menu Screen
 - The Graphical Waveform Editor
 - The Pattern Editor
 - Quick Editing
 - The Table Editor
 - The Equation Editor
 - The Sequence Editor
 - The APPL Menu
 - The UTILITY Window
- External Keyboards
 - Setting General Purpose Knob Direction
 - Formatting a Floppy Disk
 - Displaying Disk Usage
 - Screen Display Enable/Disable
 - Focused Color
 - Displaying Instrument Status
 - Internal Clock (Date and Time)
 - Resetting the Instrument
 - Connecting to a GPIB Network
 - Ethernet Networking
 - Hardcopy
 - Calibration and Diagnostics
 - Upgrading the System Software
 
 - Capturing Waveforms
 - Waveform Programming Language
 - Command Descriptions
 - Programming Examples
 - File Conversion
 - File Management
 - FG Mode
 - Waveform Mixing Mode
 - Synchronous Operation Mode (AWG710B only)
 
 - Appendices
- Appendix A: Specifications (AWG710B)
 - Appendix A: Specifications (AWG710)
 - Appendix B: Performance Verification (AWG710B)
- Conventions
 - Self Tests
 - Performance Tests
 - Operating Mode Tests
 - Amplitude and Offset Accuracy Tests (Normal Out), (except option 02)
 - Amplitude, Offset Accuracy and Rise Time Tests (Direct DA Out), (except option 02)
 - Amplitude, Offset Accuracy and Rise Time Tests (for option 02)
 - Pulse Response Tests (Normal Out), (except option 02)
 - Trigger Input Tests
 - Event Input and Enhanced Mode Tests
 - External Clock Input and VCO Out Output Tests
 - VCO OUT Output Frequency and 10 MHz Reference Input Tests
 - Marker Output Tests
 - Synchronous Operation Tests
 
 - Appendix B: Performance Verification (AWG710)
- Conventions
 - Self Tests
 - Performance Tests
 - Operating Mode Tests
 - Amplitude and Offset Accuracy Tests (Normal Out), (except option 02)
 - Amplitude, Offset Accuracy and Rise Time Tests (Direct DA Out), (except option 02)
 - Amplitude, Offset Accuracy and Rise Time Tests (for option 02)
 - Pulse Response Tests (Normal Out), (except option 02)
 - Trigger Input Tests
 - Event Input and Enhanced Mode Tests
 - 1/4 Clock Frequency and 10 MHz Reference Input Tests
 - Marker Output Tests
 
 - Appendix C: Inspection and Cleaning
 - Appendix D: Sample Waveforms
 - Appendix E: File Transfer Interface Outline
 - Appendix F: Miscellaneous
 - Appendix G: Sequence File Text Format
 
 - Index
 

Appendix B: Performance Verification (AWG710B)
AWG710&AWG710B Arbitrary Waveform Generator User Manual B-35
Figure B-16: Trigger signal and waveform output (+5 V check 1)
e. Change the pulse waveform high level to 5.35 V by using cursor keys.
f. Check that sine waves are displayed on the oscilloscope as shown in Figure 
B-7.
Figure B-17: Trigger signal and waveform output (+5 V check 2)
7. Follow the substeps below to check trigger level accuracy at –5 V: 
a. Push –, 5 and ENTER keys in this order.
b. Set the DC waveform low level of function generator to –5.35 V by using 
cursor keys.
Trigger
signal
Waveform
output
CH1
CH2
Tr i g g e r
signal
Waveform
output
CH1
CH2