User's Manual
Table Of Contents
- Title page
 - Table of Contents
 - General Safety Summary
 - Preface
 - Getting Started
 - Operating Basics
 - Reference
- Reference
 - Menu Structures
 - The Setup Menu Screen
 - The Graphical Waveform Editor
 - The Pattern Editor
 - Quick Editing
 - The Table Editor
 - The Equation Editor
 - The Sequence Editor
 - The APPL Menu
 - The UTILITY Window
- External Keyboards
 - Setting General Purpose Knob Direction
 - Formatting a Floppy Disk
 - Displaying Disk Usage
 - Screen Display Enable/Disable
 - Focused Color
 - Displaying Instrument Status
 - Internal Clock (Date and Time)
 - Resetting the Instrument
 - Connecting to a GPIB Network
 - Ethernet Networking
 - Hardcopy
 - Calibration and Diagnostics
 - Upgrading the System Software
 
 - Capturing Waveforms
 - Waveform Programming Language
 - Command Descriptions
 - Programming Examples
 - File Conversion
 - File Management
 - FG Mode
 - Waveform Mixing Mode
 - Synchronous Operation Mode (AWG710B only)
 
 - Appendices
- Appendix A: Specifications (AWG710B)
 - Appendix A: Specifications (AWG710)
 - Appendix B: Performance Verification (AWG710B)
- Conventions
 - Self Tests
 - Performance Tests
 - Operating Mode Tests
 - Amplitude and Offset Accuracy Tests (Normal Out), (except option 02)
 - Amplitude, Offset Accuracy and Rise Time Tests (Direct DA Out), (except option 02)
 - Amplitude, Offset Accuracy and Rise Time Tests (for option 02)
 - Pulse Response Tests (Normal Out), (except option 02)
 - Trigger Input Tests
 - Event Input and Enhanced Mode Tests
 - External Clock Input and VCO Out Output Tests
 - VCO OUT Output Frequency and 10 MHz Reference Input Tests
 - Marker Output Tests
 - Synchronous Operation Tests
 
 - Appendix B: Performance Verification (AWG710)
- Conventions
 - Self Tests
 - Performance Tests
 - Operating Mode Tests
 - Amplitude and Offset Accuracy Tests (Normal Out), (except option 02)
 - Amplitude, Offset Accuracy and Rise Time Tests (Direct DA Out), (except option 02)
 - Amplitude, Offset Accuracy and Rise Time Tests (for option 02)
 - Pulse Response Tests (Normal Out), (except option 02)
 - Trigger Input Tests
 - Event Input and Enhanced Mode Tests
 - 1/4 Clock Frequency and 10 MHz Reference Input Tests
 - Marker Output Tests
 
 - Appendix C: Inspection and Cleaning
 - Appendix D: Sample Waveforms
 - Appendix E: File Transfer Interface Outline
 - Appendix F: Miscellaneous
 - Appendix G: Sequence File Text Format
 
 - Index
 

The UTILITY Window
AWG710&AWG710B Arbitrary Waveform Generator User Manual 3-163
Figure 3-52: Network setup screen menu
To let the network recognize the AWG710&AWG710B Arbitrary Waveform 
Generator, set the IP address and Subnet Mask. If necessary, also set the Gateway 
address by the steps below:
1. Push UTILITY (front–panel)!Comm (bottom) to display the network setup 
screen menu.
2. Do the following steps to control the instrument through Ethernet.
a. Select Remote Control using y and b buttons.
b. Select Network.
3. Set an IP address of your AWG710&AWG710B Arbitrary Waveform 
Generator in the IP Address field. To set the IP address, there are two methods:
 Set the parameters manually:
a. Move the cursor to DHCP client field using y and b buttons, and select 
Disabled using the general purpose knob or a ' buttons.
b. Move the cursor to IP Address field using y and b buttons, and push 
Edit... side button.
c. Set the IP address in the IP Address setup dialog box.
d. If necessary, set a subnet mask in the Subnet Mask field.
Network setup parameters