Safety data sheet

Date: 2016.01.20
Reference Number: MSDS_L09L40613
2 / 6
3. HAZARD IDENTIFICATION
Under normal usage, there is no contact with electrolyte and no hazard
exists.
If exposed to high temperature or fire, cell may leak electrolyte and in
extreme cases explode. The vented gas may contain among others
Hydrogen Fluoride
4. FIRST AID
Under normal operating condition, contents of the cells are in sealed
(polymer pouch/metal can or cylinder) condition and pose no threat to the
user.
Exposure to the cell internal content happens under abusive conditions
Inhalation: Contents of open battery may cause respiratory irritation.
Move to fresh air immediately and seek medical attention
Component
Material
Formula
CAS Number
Positive Electrode
Lithium Manganese Cobaltate
Li-Mn-CoO
2
12190-79-3
Negative Electrode
Graphite
C
7440-44-0/7782-
42-5
Electrolyte
Organic Carbonate Solvent
C
3
H
4
O
3
or
similar
Lithium Hexaflurophosphate
Salt
LiPF
6
Copper
Cu
7440-50-8
Iron
Fe
7439-89-6
Aluminum
Al
7429-90-5
Plastic/Electronics