Datasheet
Data Sheet
Four isolated input channels easily handle any type of mixed signal inputs.
Portable Performance for Challenging
Environments
With 4 isolated channels and up to 7 hours of battery life, the lightweight
THS3000 Handheld Oscilloscope Series enables you to safely ma ke
floating o
r differential measurements on your bench or in the field. Now
you can tackle tough environme nts with the performance you expect from
Tektronix – safely and affordably.
Accurate
ly Measure Your Signals
With up to 200 MHz bandwidth, 4 channels, and 5 GS/s maximum sample
rate, no o
ther oscilloscope o ffers as much bandwidth a nd sample rate in a
portable handheld form factor. The THS3000 Handheld Oscilloscope Series
has 10,000 points record length per channel, enabling you to capture more
signal information at higher s ample rates to clearly see signal details. For
applications wh ere it is important to measure slow-changing signals over
long time periods, the THS3000 Series offers Roll mode that extends the
record l
ength to 30,000 points of signal information.
Safely Make Floating and Differential
Measurements
Making accurate and safe measurements on power electronics, power
semiconductors, and other electro nics applications can be challenging
when the signal reference is floating and not referenced to earth ground.
When yo
ur signal ranges from low voltage to high voltag e (kV) or you
must use probing techniques that can potentially create ground loops, the
problem is comp ounded.
To enab le floating measurements, the THS3000 Series is arch itecturally
different than most other oscilloscopes. All input channels are fully isolated
Isolated-channel technology is specified to 1000 V
RMS
maximum float voltage.
Input signa
l and float voltage maximum safety ratings.
from the m ain chassis and from each other. Additionally the power adapter
and USB interface a re fully isolated to e nsure safe measurements and
eliminate the risk of unintentional grounding or accidental short circuits.
When configured with the proper probes you can be assured you’ll be able
to make quick, safe, and accurate measurements.
Selecting the Right Probe
Maximum Safety Rating THS3000 Viewable Sig nalScope/Probe
(Attenuation)
Reference
Float Safety
Rating*
1
Input Signal
Safety
Rating
On-screen
P-P Voltage
On-screen
RMS Voltage
THS3000
(1X input)
600 V
RMS
CAT III
1000 V
RMS
CAT II
300 V
RMS
CAT III
800 V
p-p
282 V
RMS
THP0301 (10X)
300 V
RMS
CAT III
300 V
RMS
CAT III
849 V
p-p
300 V
RMS
P5150 (50X) 600 V
RMS
CAT II
1000 V
RMS
CAT II
2828 V
p-p
1000 V
RMS
P5122 (100X) 600 V
RMS
CAT II
1000 V
RMS
CAT II
2828 V
p-p
1000 V
RMS
*
1
Passive probe reference leads have no attenuation so any working voltage or overvoltage transients pass
straight through to the scope reference . Thus, a passive probe reference float rating can never exceed the
scope reference float rating.
2 www.tektronix.com