2. Use the appropriate contro l to select the
address that you want. The instrument
automatically disables an d enables the USB
port so that the new address is recog nized.
Talk/Listen
Address
a1
3. Communicate with the instrument attached to
the adapter using the control program running
on your GPIB controller.
The following parameter assumptions are made:
GPIB secondary addressing is not supported.
The defau lt GPIB primary address is 1. The GPIB primary address can only be changed from a connected Tekt ronix
USBTMC-USB488 compliant instrument designed to s up port the TEK-USB-488 GPIB to US B Ada pter, such as a DPO4000
Series oscilloscope.
The GPIB Program Message Terminator (PMT) is the GPIB end of input (EOI) line and is not con fi gurable. Messages that
assert EOI concurrent with a new line (hexadecimal 0a) character as the last data byte are supported. This means that both
EOI and EOI NL program message terminations are supported and that the NL-only termination is not supported.