User Manual

Command Descriptions
DATa:SOUrce
Sets or queries which waveform will be transferred from the oscilloscope by the
CURVe, WFMPre, or WAVFrm? queries. You can transfer only one waveform
at a time.
Group
Waveform
Syntax
DATa:SOUrce <wfm>
DATa:SOUrce?
Related Commands
CURVe, WFMPre?,
Arguments
<wfm> is the location of the waveform data that will be transferred from the
oscilloscope to the external device. Allowable values are CH<x>, MATH, and
REF<x>.
Examples
DATA:SOURCE REFB species that reference waveform REFB will be transferred
in the next CURVe? query.
DATA:SOURCE? might return REFA, indicating the source for the waveform data
that is transferred using the CURVe? command.
DATa:STARt
Sets or queries the starting data point for waveform data transfers. This command
lets you transfer partial waveforms to and from the oscilloscope.
Group
Waveform
Syntax
DATa:STARt <NR1>
DATa:STARt?
Related Commands
CURVe
Arguments
<NR1> is an integer value that ranges from 1 to 2500, and species the rst data
point that will be transferred. Data is transferred from
<NR1> to DATa:STOP or
2500, whichever is less. When DATa:STOP is less than DATa:STARt, the v alues
are swapped internally for CURVe.
2-62 TDS200, TDS1000/2000, TDS1000B/2000B, TDS2000C, TPS2000 Programmer