User Manual

Command Descriptions
Conditions
This command ap
plies to the TDS1000, TDS2000, TDS1000B, TDS2000B,
TDS2000C, and TPS2000 Series only.
Group
Trigger
Syntax
TRIGger:MAIn:VIDeo:STANDar d { NTSc | PAL }
TRIGger:MAIn:VIDeo:STANDar d?
Arguments
NTSC (default) species the NTSC video standard.
PAL spec ies the PAL or SECAM video standard.
Examples
TRIGGER:MAIN:VIDEO:STANDAR
DNTSC
selects the NTSC standard for the
video trigger.
TRIGger:MAIn:VIDeo:SYNC
Sets or queries the type for the video trigger sync. This is equivalent to selecting
the Sync option in the Trigger/Video menu.
Group
Trigger
Syntax
TRIGger:MAIn:VIDeo:SYNC { FIELD | LINE | ODD | EVEN |
LINENum }
TRIGger:MAIn:VIDeo:SYNC?
Arguments
FIELD species that triggering occur on the vertical sync pulse.
LINE species that triggering occur on the horizontal sync pulse.
ODD species triggering on odd elds (TDS1000, TDS2000, TDS1000B,
TDS2000B, TDS2000C, and TPS2000 Series only).
EVEN species triggering on even elds (TDS1000, TDS2000, TDS1000B,
TDS2000B, TDS2000C, and TPS2000 Series only).
LINENum sets the oscilloscope to trigger on a speci c line number, which
is specied through TRIGger:MAIn:VIDeo:LINE (TDS1000, TDS2000,
TDS1000B, TDS2000B, TDS2000C, and TPS2000 Series only).
Examples
TRIGGER:MAIN:VIDEO:SYNC FIELD selec
ts the vertical synchronization pulse
for the video trigger sync.
TDS200, TDS1000/2000, TDS1000B/2000B, TDS2000C, TPS2000 Programmer 2-177