Conditions
This command ap
plies to the TDS1000, TDS2000, TDS1000B, TDS2000B,
TDS2000C, and TPS2000 Series only.
Group
Trigger
Syntax
TRIGger:MAIn:PULse:WIDth:P OLarity { POSITIVe | NEGAtive }
TRIGger:MAIn:PULse:WIDth:P OLarity?
Arguments
POSITIVe polarity specifics pulses with a rising leading edge.
NEGAtive polarity specifies pulses with a falling leading edge.
TRIGger:MAIn:PULse:WIDth:WHEN
Sets or queries the trigger conditions for the pulse trigger. This is equivalent to
setting theWhen option in the Pulse Trigger menu.
Conditions
This command applies to the TDS1000, TDS2000, TDS1000B, TDS2000B,
TDS2000C, and TPS2000 Series only.
Group
Trigger
Syntax
TRIGger:MAIn:PULse:WIDth:W HEN { EQual | NOTEqual | INside |
OUTside }
TRIGger:MAIn:PULse:WIDth:W HEN?
Arguments
EQual triggers on the trailing edge of pulses of the specified width.
NOTEQual triggers when a pulse trailing edge occurs before the specified width,
or a pulse continues longer than the specified width without a trailing edge.
INside < triggers on the trailing edge of any pulses that are narrower than the
specified width.
OUTside (greater than; also called time-out trigger) triggers when a pulse
continues longer that the specified width.
TRIGger:MAIn:PULse:WIDth:WIDth
Sets or queries the width for the pulse trigger. This is equivalent to setting the
Width option by using the Pulse Trigger menu and the TRIGGER knob.
TDS200, TDS1000/2000, TDS1000B/2000B, TDS2000C, TPS2000 Programmer 2-173