User Manual

Command Descriptions
Conditions
This command ap
plies to the TPS2000 Series with TPS2PWR1 Power Analysis
Module only.
Group
Power Measur
ement
Syntax
HARmonics:ENABle { ON | OFF }
HARmonics:ENABle?
Arguments
ON causes the oscilloscope t o display the harmonics menu and turn on Harmonics
analysis.
OFF causes the oscilloscope to display the CH1 menu.
Examples
HARMONICS:ENABLE ON causes the oscilloscope to display the harmonics menu.
HARMONICS:ENABLE? might return OFF, indicating that the harmonics menu
is turned off.
HARmonics:FREquency? (Query Only)
Returns the frequency of the selected harmonic.
Group
Power Measurement
Syntax
HARmonics:FREquency?
Returns
<NR3>
Examples
HARMONICS:FREQUENCY? might return 3.60576923E2 , indicating that the
frequency o f the selected harmonic is 360.57 Hz.
HARmonics:HRMS? (Query Only)
Returns the RMS amplitude of the selected harmonic in the same units as the
source waveform.
Group
Power Measurement
Syntax
HARmonics:HRMS?
2-88 TDS200, TDS1000/2000, TDS1000B/2000B, TDS2000C, TPS2000 Programmer