User Manual

Repair
Cable
1. Remove the transformer and circuit board
as described in the previous procedures.
2. Unsolder the two switch wires.
3. Proceed to the Compensation Bo x
procedure to detach the cable from the
compensation box. (See page 77.)
4. To reassemble the probe af ter replacing
the cable, perform steps 1 through 3 of this
procedure in reverse. (See the following
Caution sta tement.)
CAUTION. To avoid d amaging the wires inside the probe, carefully dre ss the wire s in the lower body half to avoid contact with
theslideassembly.
To avoid damaging the switch contacts, exercise care when tting the slide bac k into the probe body. Aligning the switch
contacts requires precision.
76 TCP0150 Current Probe Instruction Manual