Datasheet
Trigger system
Trigger modes Auto, Normal, and Single
Trigger holdoff range 20 ns to 8 s
Trigger types
Edge Positive or negative slope on any channel. Coupling includes DC, HF reject, LF reject, and noise reject.
Pulse width Trigger on width of positive or negative pulses that are >, <, =, or ≠ a specified period of time.
Runt Trigger on a pulse that crosses one threshold but fails to cross a second threshold before crossing the first again.
Trigger coupling analog channels DC, Noise Reject, High Freq Reject, Low Freq Reject.
Sensitivity, edge–type trigger, DC
coupled
Trigger Source
Sensitivity
70 MHz models 0.4 division
100 MHz models 0.5 division
200 MHz models 0.7 division
Trigger level ranges Input channels: ± 4.90 divisions from center screen
Data storage
Nonvolatile memory retention
time, typical
No time limit for Front Panel Settings, saved waveforms, setups, and calibration constants.
Real-Time clock A programmable clock providing time in years, months, days, hours, minutes, and seconds.
Waveform measurements
Cursors Time, amplitude and screen.
Automated measurements 32, of which up to six can be displayed on-screen at any one time. Measurements include: Period, Frequency, Rise Time, Fall
Time, Positive Duty Cycle, Negative Duty Cycle, Positive Pulse Width, Negative Pulse Width, Burst Width, Phase, Positive
Overshoot, Negative Overshoot, Peak to Peak, Amplitude, High, Low, Max, Min, Mean, Cycle Mean, RMS, Cycle RMS, Positive
Pulse Count, Negative Pulse Count, Rising Edge Count, Falling Edge Count, Area, Cycle Area, Delay FR, Delay FF, Delay FR,
and Delay RR.
Gating Isolate the specific occurrence within an acquisition to take measurements on, using either the screen, between waveform cursors
or full record length.
Waveform math
Arithmetic Add, subtract, and multiply waveforms.
FFT Spectral magnitude. Set FFT Vertical Scale to Linear RMS or dBV RMS, and FFT Window to Rectangular, Hamming, Hanning, or
Blackman-Harris.
Digital Storage Oscilloscope
www.tektronix.com 11