User manual
Table Of Contents
- toc
- General safety summary
- Compliance Information
- Preface
- Getting Started
- Operating Basics
- Understanding Oscilloscope Functions
- Application Examples
- Taking Simple Measurements
- Using Autorange to Examine a Series of Test Points
- Taking Cursor Measurements
- Analyzing Signal Detail
- Capturing a Single-Shot Signal
- Measuring Propagation Delay
- Triggering on a Specific Pulse Width
- Triggering on a Video Signal
- Analyzing a Differential Communication Signal
- Viewing Impedance Changes in a Network
- Data Logging
- Limit Testing
- Math FFT
- USB Flash Drive and Device Ports
- USB Flash Drive Port
- File Management Conventions
- Saving and Recalling Files With a USB Flash Drive
- Using the Save Function of the Print Front Panel Button
- USB Device Port
- Installing the PC Communications Software on a PC
- Connecting to a PC
- Connecting to a GPIB System
- Command Entry
- Connecting to a Printer
- Printing a Screen Image
- Reference
- Appendix A: Specifications
- Appendix B: TPP0101 and TPP0201 Series 10X Passive Probes Inform
- Appendix C: Accessories
- Appendix D: Cleaning
- Appendix E: Default Setup
- Appendix F: Font Licenses

Appendix A: Specifications
Table 6: Gen eral Specifications (cont.)
Characteris
tic
Description
Environmental
Operating 0° C to +50° C
, with 5° C/minute
maximum gradient, non-condensing,
up to 3000m altitude
Temperature
Nonoperat
ing
-40° C to +71° C, with 5° C/minute
maximum gradient
Cooling Method Convection cooled
Operatin
g:
5% to 85% r
elative humidity ( % RH) at up to +40° C
5% to 45% RH above +40° C up to +50° C, non-condensing, and as limited by a
Maximum Wet-Bulb Temperature of +37° C (derates relative humidity to 45 % RH at
+50° C)
Humidity
: Operating and
Non-Operating
Non-Operating: 5% to 85% RH (Relative Humidity) at up to +40° C,
5% to 45%
RH above +40° C up to +50° C, non-condensing.
Above +50° C limited by a Maximum Wet-Bulb Temperature of +37° C (derates
relative humidity to 12% RH at +71° C)
Operating: Up to 3000 meters (10,000 feet)Altitude: Operating and
Non-Operating
Non-Op
erating:
Up to 30
00 meters (10,000 feet).
Mechanical
Requi
rements that follow are nominal:
Height
158.0 mm (6.22 in.)
Widt
h
326.3 mm (12.85 in)
Overa
ll Dimensions
Depth
124.
1 mm (4.88 in)
Requirements that follow are nominal:
Stand alone instrument 2.0 kg (4.4 lbs)
With accessories
2.2
kg (4.9 lbs)
Weight
When packaged for domestic shipment 3.6 kg (8 lbs)
TBS1000 Series Oscilloscopes User Manual 113