User's Manual

3-82
Section 3 — Menu Descriptions
GPI & PBus Triggers Menu
The PBus Device and Function assignments are made in the
Peripheral Interface menu under config/ext if/peripheral if.
SELECT GPI — Selects the GPI Output (1 through 8) to which you
may attach an E-MEM register or keyframe. The trigger numbers
correspond to the physical connections made to the GPI Output
connectors on the rear of the switcher frame.
ATTACHAttaches the selected PBus or GPI trigger to the
indicated E-MEM register or keyframe (MISC), or turns the trigger
OFF.
MISC notation in the upper right-hand corner of the screen
reminds you that the Attach GPI/PBus function operates through
the MISC level on the E-MEM Enables panel,
Effect: is the
currently selected E-MEM register, and Keyframe: is the location
of the Time Cursor on the Master Timeline.
FIRE ... — Test fires the selected (highlighted) trigger or GPI.
GPI & PBUS TRIGGERS MENU
MISC
E-MEM / gpi & pbus triggers
ATTACH
PERIPH
SELECT
PERIPH
ATTACH
GPI
SELECT
GPI
FIRE
ATTACHED
FIRE
1
FIRE
ATTACHED
FIRE
A
B
C
D
E
F
G
H
DEVICE
-
-
-
-
-
-
-
FUNCTION
-
-
-
-
-
-
-
A
1
E-MEM LEVEL
-
-
-
-
-
-
-
-
PERIPHERAL TRIGGERS (PBUS 2)
-6A
-
2
3
4
5
6
7
8
1
E-MEM LEVEL
-
-
-
-
-
-
-
-
GPI OUTPUT TRIGGERS
-6
1
OFF
MISC
1 OFF
Effect: Keyframe: