Datasheet
Auxiliary output Rear-panel BNC connector. Output can be configured to provide a positive or negative pulse out when the oscilloscope triggers,
the internal oscilloscope reference clock out, or an AFG sync pulse
Characteristic Limits
Vout (HI) ≥ 2.5 V open circuit; ≥ 1.0 V into a 50 Ω load to ground
Vout (LO) ≤ 0.7 V into a load of ≤ 4 mA; ≤0.25 V into a 50 Ω load to
ground
Kensington-style lock Rear-panel security slot connects to standard Kensington-style lock
LXI Class: LXI Core 2016
Version: 1.5
Power source
Power
Power consumption 400 Watts maximum
Source voltage 100 - 240 V ±10% at 50 Hz to 60 Hz
115 V ±10% at 400 Hz
Physical characteristics
Dimensions Height: 9.8 in (249 mm), feet folded in, handle to back
Height: 13.8 in (351 mm) feet folded in, handle up
Width: 15.9 in (405 mm) from handle hub to handle hub
Depth: 6.1 in (155 mm) from back of feet to front of knobs, handle up
Depth: 10.4 in (265 mm) feet folded in, handle to the back
Weight < 16.8 lbs (7.6 kg)
Cooling The clearance requirement for adequate cooling is 2.0 in (50.8 mm) on the right side of the instrument (when viewed from the
front) and on the rear of the instrument
Rackmount configuration 7U (with optional RM4 Rackmount Kit)
Environmental specifications
Temperature
Operating +0 °C to +50 °C (32 °F to 122 °F)
Non-operating -30 °C to +70 °C (-22 °F to 158 °F)
Humidity
Operating 5% to 90% relative humidity (% RH) at up to +40 °C
5% to 50% RH above +40 °C up to +50 °C, noncondensing, and as limited by a maximum wet-bulb temperature of +39 °C
Non-operating 5% to 90% relative humidity (% RH) at up to +40 °C
5% to 50% RH above +40 °C up to +50 °C, noncondensing, and as limited by a maximum wet-bulb temperature of +39 °C
Datasheet
Input-Output ports
30 www.tek.com