Datasheet

Amplitude measurements Amplitude, Maximum, Minimum, Peak-to-Peak, Positive Overshoot, Negative Overshoot, Mean, RMS, AC RMS, Top, Base, and
Area
Timing measurements Period, Frequency, Unit Interval, Data Rate, Positive Pulse Width, Negative Pulse Width, Skew, Delay, Rise Time, Fall Time,
Phase, Rising Slew Rate, Falling Slew Rate, Burst Width, Positive Duty Cycle, Negative Duty Cycle, Time Outside Level, Setup
Time, Hold Time, Duration N-Periods, High Time, and Low Time
Measurement statistics Mean, Standard Deviation, Maximum, Minimum, and Population. Statistics are available on both the current acquisition and all
acquisitions
Reference levels User-definable reference levels for automatic measurements can be specified in either percent or units. Reference levels can be
set to global for all measurements, per source channel or signal, or unique for each measurement
Gating Screen, Cursors, Logic, Search, or Time. Specifies the region of an acquisition in which to take measurements. Gating can be set
to Global (affects all measurements set to Global) or Local (all measurements can have a unique Time gate setting; only one Local
gate is available for Screen, Cursors, Logic, and Search actions).
Measurement plots Time Trend, Histogram, and Spectrum plots are available for all standard measurements
Power analysis adds the following:
Measurements Input Analysis (Frequency, V
RMS
, I
RMS
, voltage and current Crest Factors, True Power, Apparent Power, Reactive Power, Power
Factor, Phase Angle, Harmonics, Inrush Current, Input Capacitance )
Amplitude Analysis (Cycle Amplitude, Cycle Top, Cycle Base, Cycle Maximum, Cycle Minimum, Cycle Peak-to-Peak)
Timing Analysis (Period, Frequency, Negative Duty Cycle, Positive Duty Cycle, Negative Pulse Width, Positive Pulse Width)
Switching Analysis (Switching Loss, dv/dt, di/dt, Safe Operating Area, R
DSon
)
Output Analysis (Line Ripple, Switching Ripple, Efficiency, Turn-on Time, Turn-off Time)
Measurement Plots Harmonics Bar Graph, Switching Loss Trajectory Plot, and Safe Operating Area
Waveform math
Number of math waveforms Unlimited
Arithmetic Add, subtract, multiply, and divide waveforms and scalars
Algebraic expressions Define extensive algebraic expressions including waveforms, scalars, user-adjustable variables, and results of parametric
measurements. Perform math on math using complex equations. For example (Integral (CH1 - Mean(CH1)) X 1.414 X VAR1)
Math functions Invert, Integrate, Differentiate, Square Root, Exponential, Log 10, Log e, Abs, Ceiling, Floor, Min, Max, Degrees, Radians, Sin,
Cos, Tan, ASin, ACos, and ATan
Relational Boolean result of comparison >, <, ≥, ≤, =, and ≠
Logic AND, OR, NAND, NOR, XOR, and EQV
Filtering function User-definable filters. Users specify a file containing the coefficients of the filter
FFT functions Spectral Magnitude and Phase, and Real and Imaginary Spectra
FFT vertical units Magnitude: Linear and Log (dBm)
Phase: Degrees, Radians, and Group Delay
FFT window functions Hanning, Rectangular, Hamming, Blackman-Harris, Flattop2, Gaussian, Kaiser-Bessel, and TekExp
4 Series MSO
Waveform measurements
www.tek.com 25