Datasheet

Ethernet Bus (option 4-
SRENET):
Trigger on Start of Frame, MAC Addresses, MAC Q-tag, MAC Length/Type, MAC Data, IP Header, TCP Header, TCP/IPV4 Data,
End of Packet, and FCS (CRC) Error on 10BASE-T and 100BASE-TX buses
Audio (I
2
S, LJ, RJ, TDM) Bus
(option 4-SRAUDIO):
Trigger on Word Select, Frame Sync, or Data. Maximum data rate for I
2
S/LJ/RJ is 12.5 Mb/s. Maximum data rate for TDM is
25 Mb/s
MIL-STD-1553 Bus (option 4-
SRAERO):
Trigger on Sync, Command (Transmit/Receive Bit, Parity, Subaddress / Mode, Word Count / Mode Count, RT Address), Status
(Parity, Message Error, Instrumentation, Service Request, Broadcast Command Received, Busy, Subsystem Flag, Dynamic Bus
Control Acceptance, Terminal Flag), Data, Time (RT/IMG), and Error (Parity Error, Sync Error, Manchester Error, Non-contiguous
Data) on MIL-STD-1553 buses
ARINC 429 Bus (option 4-
SRAERO):
Trigger on Word Start, Label, Data, Label and Data, Word End, and Error (Any Error, Parity Error, Word Error, Gap Error) on
ARINC 429 buses up to 1 Mb/s
Acquisition system
Sample Acquires sampled values
Peak Detect Captures glitches as narrow as 640 ps at all sweep speeds
Averaging From 2 to 10,240 waveforms
Envelope Min-max envelope reflecting Peak Detect data over multiple acquisitions
High Res Applies a unique Finite Impulse Response (FIR) filter for each sample rate that maintains the maximum bandwidth possible for that
sample rate while preventing aliasing and removing noise from the oscilloscope amplifiers and ADC above the usable bandwidth
for the selected sample rate.
High Res mode always provides at least 12 bits of vertical resolution and extends all the way to 16 bits of vertical resolution at
≤ 125 MS/s sample rates.
FastAcq
®
FastAcq optimizes the instrument for analysis of dynamic signals and capture of infrequent events by capturing >500,000 wfms/s
(one channel active; >100K wfms/s with all channels active).
Roll mode Scrolls sequential waveform points across the display in a right-to-left rolling motion, at timebase speeds of 40 ms/div and slower,
when in Auto trigger mode.
FastFrame
Acquisition memory divided into segments.
Maximum trigger rate >5,000,000 waveforms per second
Minimum frame size = 50 points
Maximum Number of Frames: For frame size ≥ 1,000 points, maximum number of frames = record length / frame size.
For 50 point frames, maximum number of frames = 1,500,000
Waveform measurements
Cursor types Waveform, V Bars, H Bars, and V&H Bars
DC voltage measurement
accuracy, Average acquisition
mode
Measurement Type
DC Accuracy (In Volts)
Average of ≥ 16 waveforms ±((DC Gain Accuracy) * |reading - (offset - position)| + Offset
Accuracy + 0.1 * V/div setting)
Delta volts between any two averages of ≥ 16 waveforms
acquired with the same oscilloscope setup and ambient
conditions
±(DC Gain Accuracy * |reading| + 0.05 div)
Automatic measurements 36, of which an unlimited number can be displayed as either individual measurement badges or collectively in a measurement
results table
Datasheet
Trigger system
24 www.tek.com