User's Manual

Performance Tests
AWG2005 Service Manual
4Ć19
Procedure:
1.        
a.     Connect the AWG2005 CH1 output
connector through the coaxial cable to the CH1 vertical input conĆ
nector on the oscilloscope (see Figure 4Ć7).
OscilloscopeAWG2005
AWG2005
Figure 4Ć7:ăWaveform Advance Mode Initial Test Hookup
b.   
Vertical CH1
CH1 coupling DC
CH1 0.2ĂV/div.
CH1 input impedance 50Ă
Horizontal
Sweep 50õs/div.
Trigger
Source CH1
Coupling DC
Slope Positive
Level 0ĂV
Mode Auto
2.         
a.     Push UTILITYMiscConfig...ReĆ
set to FactoryO.K.
b.   
Push MODEWaveform AdvanceSlope to highlight PosiĆ
tive.
Select Level from the side menu, and turn the general purpose
knob to select a 1.0ĂV level.
Check that the side menu Run highlights Continuous. If necesĆ
sary, push Run to select Continuous.
c.   