User's Manual
Performance Tests
AWG2005 Service Manual
4Ć19
Procedure:
1.
a. Connect the AWG2005 CH1 output
connector through the coaxial cable to the CH1 vertical input conĆ
nector on the oscilloscope (see Figure 4Ć7).
OscilloscopeAWG2005
AWG2005
Figure 4Ć7:ăWaveform Advance Mode Initial Test Hookup
b.
Vertical CH1
CH1 coupling DC
CH1 0.2ĂV/div.
CH1 input impedance 50ĂΩ
Horizontal
Sweep 50õs/div.
Trigger
Source CH1
Coupling DC
Slope Positive
Level 0ĂV
Mode Auto
2.
a. Push UTILITYMiscConfig...ReĆ
set to FactoryO.K.
b.
Push MODEWaveform AdvanceSlope to highlight PosiĆ
tive.
Select Level from the side menu, and turn the general purpose
knob to select a 1.0ĂV level.
Check that the side menu Run highlights Continuous. If necesĆ
sary, push Run to select Continuous.
c.